Search PubMedSearch

PubMed · 7077310

Code blue--factitious cyanosis.

Abstract

The authors report a case of factitious cyanosis in a psychiatric inpatient. To their knowledge, this is the first report of factitious cyanosis in the medical literature. They discuss the relationship of isolated factitious signs and symptoms to Munchausen syndrome and other psychiatric diagnoses. They explore the underlying dynamic of displaced anger in this patient. They suggest that avoiding confrontation with these patients may lead to a better therapeutic outcome and caution physicians to be alert to the possibility of factitious etiology when presented with confusing symptom clusters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C H Kellner, S Eth. 1982. Code blue--factitious cyanosis.. https://doi.org/10.1097/00005053-198206000-00008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Acrocyanosis].

Explore the source record for details and available documents.

Cyanosis

Mechanism of cyanotic spells in tetralogy of Fallot--the missing link?

The mechanism of cyanotic spells in patients with tetralogy of Fallot is not clear. Increases in infundibular contractility or hyperpnoea have been considered as the key factors, but this explanation appears inadequate. In this review, arguments are presented against these commonly held views. Preliminary evidence is synthesised in favour of another more plausible hypothesis that cyanotic spells may result from mechanoreceptor stimulation from the right ventricle. Increased contractility (due to catecholamines) and decreased right ventricular size (due to various factors) can trigger a reflex resulting in hyperventilation, some peripheral vasodilation without bradycardia, and this may initiate a spell. This mechanism explains most of the precipitating events and many other issues about cyanotic spells more satisfactorily.

Cyanosis

Oxygen desaturation during sleep in infants and young children with congenital heart disease.

Oxygen saturation (SaO2) during sleep and pulmonary functions were evaluated in 19 infants with congenital heart disease, aged 6 +/- 4 months, and in 11 normal infants, aged 8 +/- 5 months, to determine whether infants with congenital heart disease have more frequent oxygen desaturation during sleep and, if so, its relationship to underlying pulmonary function. Infants with congenital heart disease were classified as acyanotic (n = 11) or cyanotic (n = 8) on the basis of their aortic SaO2 at the time of cardiac catheterization (greater or less than 90% SaO2). Pulmonary function tests included respiratory rate, functional residual capacity, total respiratory system compliance, and maximal flows at functional residual capacity. Significant differences were found in the values for the lowest SaO2 of each 5-minute epoch (SaO2L) averaged during the entire sleep time (normal 94% +/- 2%, acyanotic 90% +/- 3%, and cyanotic 74% +/- 4%; p less than 0.01). The three groups also differed significantly in frequency distributions of percentage of total sleep time with SaO2L less than 90% (SaO2%T) (normal 10% +/- 17%, acyanotic 36% +/- 34%, and cyanotic 97% +/- 4%; p less than 0.05). Compared with the control group, the acyanotic group had a higher respiratory rate (66 +/- 19 breaths/min vs 35 +/- 6 breaths/min; p less than 0.01), a lower tidal volume (65% +/- 29% predicted vs 105% +/- 18% predicted; p less than 0.01), and a lower total respiratory compliance (59% +/- 18% predicted vs 106% +/- 30% predicted; p less than 0.01). A negative correlation existed between SaO2%T and aortic SaO2 (R2 = 0.64; p less than 0.01). We conclude that oxygen desaturation occurs during sleep in infants with congenital heart disease; the presence of desaturation appears to be related to the initial degree of hypoxemia and the presence of abnormal pulmonary function.

Cyanosis