Dynamic computed tomography through interpolation.

Abstract

A method is proposed to reduce the requirement on the scanning speed for dynamic computed tomography of relatively fast moving objects such as the heart. From the projections measured at different times, a set of optimal projections is computed for reconstructing the image at any specified time within a permissible interval. In the method, the corresponding characteristic features of the measured projections at the same viewing angle are matched optimally by a nonlinear transformation. The matched projections are then used in an interpolation procedure to compute the projections required at the specified time. The method has been tested with mathematical phantoms that undergo partial expansion, contraction, and translational motion. The results show that the proposed method can provide acceptable images from data collected at scanning speeds that would otherwise produce severely blurred images by conventional methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H C Lee, C H Leung. 1982. Dynamic computed tomography through interpolation.. https://doi.org/10.1097/00004728-198202000-00022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From antianginal drugs to myocardial cytoprotective agents.

The existing major classes of antianginal drugs improve quality of life in patients with coronary artery disease, but mortality in these patients remains unacceptably high. In order to limit the complications of the disease, it is vital to limit myocyte loss. Potentially, this can be achieved not only by prophylaxis, but also by protection, against ischemia. Any therapy that increases myocardial resistance to ischemia will protect against cell death and prolong the life of the myocyte, and possibly the patient. The mechanisms of cell damage during ischemia, and possible therapeutic interventions, are discussed.

Heart

A phased array coil for human cardiac imaging.

A prototype cardiac phased array receiver coil was constructed that comprised a cylindrical array and a separate planar array. Both arrays had two coil loops with the same coil dimensions. Data acquisition with the cylindrical array placed on the human chest, and the planar array placed under the back, yielded an overall enhancement of the signal-to-noise ratio (SNR) over the entire heart by a factor of 1.1-2.85 over a commercially available flexible coil and a commercially available four-loop planar phased array coil. This improvement in SNR can be exploited in cardiac imaging to increase the spatial resolution and reduce the image acquisition time.

Heart

Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.

A spilldown correction method is proposed for the thallium-201 window image in simultaneous dual-isotope technetium-99m/thallium-201 single-photon emission tomographic (SPET) imaging based on a single acquisition into three energy windows. In this method, images are simultaneously acquired in two standard energy windows over the 99mTc and 201Tl photopeak regions and a third spilldown window adjacent to the 201Tl window. Using a Monte Carlo simulation of SPET, the fractional amount of 99mTc and 201Tl spilldown in the 201Tl window with respect to the total counts from the spilldown window, k12, was calculated for simulated images of point sources at varying depths within a water-filled elliptical tub phantom. When applied to experimental acquisitions, k12, multiplied by the total counts from the spilldown window, is then subtracted from the 201Tl window image to produce the corrected image. However, for successful applications in SPET, k12 must be determined on a projection-by-projection basis since k12 is depth dependent. Thus, a regression relation was obtained between k12 and the total count ratio of the spilldown to 99mTc windows, k23. The spilldown correction method was applied to 201Tl photopeak images of an extended source distribution in uniform and nonuniform attenuating media with dual-isotope 99mTc/201Tl and single-isotope 201Tl. A marked improvement in image contrast was observed between the corrected and uncorrected 201Tl window images. The average count ratio of uncorrected dual-isotope 201Tl/single-isotope 201Tl was 3.08 for uniform and 2.99 for non-uniform attenuating media.(ABSTRACT TRUNCATED AT 250 WORDS)

Heart