Search PubMedSearch

PubMed · 7068303

Fibronectin.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Stasko, R L De Villez. 1982. Fibronectin.. https://doi.org/10.1111/j.1365-4362.1982.tb00499.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An autologous fibrin tissue adhesive with greater bonding power.

OBJECTIVE: To describe and evaluate an autologous fibrin tissue adhesive (AFTA) that uses a combination of ethanol and freezing to precipitate fibrinogen (AFTA-E). DESIGN: The bonding power of AFTA-E was compared with that of a conventional AFTA based on ammonium sulfate precipitation of fibrinogen (AFTA-A). In this study, Silastic, porcine dermis, and human dura mater blocks were bonded together for 10 and 30 minutes with AFTA-E or AFTA-A. The blocks were then separated and the bonding power was measured. The efficacy of AFTA-E was also evaluated after a 24-hour refrigeration. SETTING: The Department of Otolaryngology Research Laboratory at the University of Illinois Eye and Ear Infirmary, Chicago, Ill. PARTICIPANTS: Blood was drawn from 86 healthy volunteers and AFTA-E and/or AFTA-A was manufactured. RESULTS: The AFTA-E was shown statistically to bond stronger than the AFTA-A. In addition, it was found that the efficacy of AFTA-E was unchanged after a 24-hour refrigeration. CONCLUSIONS: The improved AFTA, AFTA-E, is a superior alternative to the conventional AFTA-A. Furthermore, AFTA-E can be manufactured before surgery and stored, thus minimizing preparation time during surgery.

Adhesiveness

Apatite coated on organic polymers by biomimetic process: improvement in its adhesion to substrate by glow-discharge treatment.

A dense, uniform, and highly biologically active bone-like apatite layer can be formed in arbitrary thickness on any kind and shape of solid substrate surface by the following biomimetic method at ordinary temperature and pressure: First, a substrate is set in contact with particles of bioactive CaO-SiO2-based glass soaked in a simulated body fluid (SBF) with inorganic ion concentrations nearly equal to those of human blood plasma so that a number of apatite nuclei are formed on the substrate. Second, the substrate is soaked in another solution with ion concentrations 1.5 times those of SBF (1.5SBF) so that the apatite nuclei grow in situ. In the present study, organic polymer substrates were treated with glow-discharge in O2 gas atmosphere, then subjected to the above-mentioned biomimetic process. The induction periods for the apatite nucleation on all the examined organic polymers were reduced from 24 to 6 h, with glow-discharge treatment. The adhesive strengths of the formed apatite layer to the substrates increased from about 4 to 10 MPa for poly(ethylene terephthalate) and poly-ether sulfone, and from 1 approximately 2 to 6 approximately 7 MPa even for poly(methyl methacrylate), polyamide 6 and polyethylene. It is supposed that highly polar groups such as carbonyl, ester, hydroxyl, and carboxyl ones formed by glow-discharge treatment increased the affinity of a silicate ion with the substrates to decrease the induction period, and also increased the affinity of the apatite with the substrate to increase the adhesive strength.(ABSTRACT TRUNCATED AT 250 WORDS)

Adhesiveness

Augmentation of meniscal repairs with cyanoacrylate glue.

Cyanoacrylate glues are biodegradable, bacteriostatic, hemostatic adhesives which have been used experimentally in surgical procedures on many tissues. This study evaluates the efficacy of cyanoacrylate glues used for in vitro bovine meniscus repair. Our hypothesis was that a local adhesive might improve fixation of meniscus tears reapproximated with suture, or obviate the need for suture. Three high-viscosity flexible cyanoacrylate glues were tested and their tensile strengths compared to those of suture alone and suture augmented with glue. The flexible formulation enables the glue to deform with the meniscus during movement of the knee joint. Bovine meniscus tissue was used as the model to compare the tensile strength at the meniscus repair site using the 300 cps glue in combination with 3-0 prolene suture, 300 cps cyanoacrylate glue alone, and suture alone. Twenty specimens were included in each repair group, and the peak load to failure was normalized for surface area and subjected to analysis of variance. Results of the analysis showed that the peak load to failure of the combination of cyanoacrylate glue plus suture was significantly higher than that of glue alone (P < .0001), but not significantly higher than that of suture alone (P = .18). However, in tissues repaired with suture, tissue separation at the tear site was noted almost immediately after distraction started, as a result of the elasticity of the suture. The combination of cyanoacrylate glue plus suture provided the maximum tensile strength before tissue separation. Because tissue separation may interfere with the meniscal healing process, glue used in combination with suture appears to offer some advantage mechanically.(ABSTRACT TRUNCATED AT 250 WORDS)

Adhesiveness