Abstract

Initial clinical results are described for a new method of digital radiography based on high-detail self-scanning linear diode arrays which overcome many of the limitations of present film or other digital methods. The technique uses a fan-shaped x-ray beam to produce a nearly scatter-free image on a phosphor strip that is fiber-optically coupled to six self-scanning arrays of light-sensitive diodes spaced 0.025 mm, thus providing 6,144 discrete sensors across the field of view. Because these diodes have a greatly expanded dynamic range and operate at very low noise, it becomes possible to visualize small density differences or contrast below 1% both in the light and dark areas of the image. Because of the efficiency of detection and display, radiation doses can be reduced for a given information content. Our preliminary clinical studies have shown to broad application of our method in examining the chest and abdomen and in performing intravenous digital arteriography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Sashin, E J Sternglass, B S Slasky, K M Bron, J M Herron, W H Kennedy, L Shabason, J Boyer, A E Pollitt, R E Latchaw, B R Girdany, R W Simpson. 1982. Diode array digital radiography: initial clinical experience.. https://doi.org/10.2214/ajr.139.6.1045. https://searchpubmed.org/record/pubmed%3A6983247/diode-array-digital-radiography-initial-clinical-experience

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗