Search PubMedSearch

PubMed · 6963252

[Endodontic surgery].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Arens. 1982-09-23. [Endodontic surgery].. https://pubmed.ncbi.nlm.nih.gov/6963252/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of sterilization by gamma irradiation and of thermal annealing on creep of hydroxyapatite-reinforced polyethylene composites.

Sterilization of medical devices by gamma (gamma)-irradiation is common. The effect of irradiation on a bone replacement material, HAPEX (hydroxyapatite-reinforced polyethylene composite), was investigated. Unfilled and hydroxyapatite-filled polyethylene at 0.20 and 0.40 filler volume fractions were gamma-irradiated at 2.5 Mrad, and the modified properties were studied by differential scanning calorimetery, isochronous experiments, and creep tests. The effect of thermal annealing of the samples from 140 degrees C also was examined. The results suggest that both irradiation and annealing increase creep resistance of the materials. These are associated with the formation of crosslinks and an increase in crystallinity, respectively.

Biocompatible Materials

Preparation and characterization of heparin-containing SBS-g-DMAEMA copolymer membrane.

The grafting of dimethyl amino ethyl methacrylate (DMAEMA) onto styrene-butadiene-styrene triblock copolymer (SBS) membrane was subsequently conducted by UV-radiation induced graft copolymerization without degassing to obtain the SBS-g-DMAEMA copolymer membrane. The substituted amino groups on the SBS-g-DMAEMA graft copolymer membrane were quaternized with iodomethane, and then the membrane was treated with heparin to prepare the heparin-containing SBS-g-DMAEMA copolymer membrane (SBS-g-DMAEMA-HEP). The graft copolymer membrane (SBS-g-DMAEMA) and the heparin-containing SBS-g-DMAEMA copolymer membrane (SBS-g-DMAEMA-HEP) were characterized by FTIR spectroscopy. The heparin content was determined by toluidine blue heparin assay. Contact angle, water content, and protein adsorption of fibrinogen and albumin experiments were also performed to evaluate the effect of graft amount and heparin content on the biocompatibility of SBS-g-DMAEMA and SBS-g-DMAEMA-HEP graft copolymer membranes. By using Kaelble's equation, the surface tension of SBS-g-DMAEMA and SBS-g-DMAEMA-HEP were determined. It was found that with increasing grafting amount and the heparin content, the surface tension and water content of SBS-g-DMAEMA membrane increased, whereas the contact angle decreased. The amount of the adsorption of albumin and fibrinogen decreased with increasing graft amount and heparin content. However, there was a minimum for adsorption of proteins in the SBS-g-DMAEMA and SBS-g-DMAEMA-HEP membranes.

Biocompatible Materials

A novel fiber-optic pH sensor incorporating carboxy SNAFL-2 and fluorescent wavelength-ratiometric detection.

A fiber-optic pH sensor was prepared using the self-referencing fluorescent pH probe carboxy seminaphtho-fluorescein (SNAFL-2). The ratio of the emission from the base form of this dye and the emission near the isoemissive point is insensitive to variations in the excitation intensity and photobleaching. The carboxy SNAFL-2 and a photoaffinity crosslinker, 4-azido-2,3,5,6-tetrafluorobenzoic acid, succinimidyl ester, were attached onto poly(acrylamide-co-vinylamine) to form a hydrophilic functional membrane for the fiber-optic sensor. Photo crosslinking was used to create a crosslinked pH-sensing membrane and covalently bind the membrane onto the surface of the PMMA optical fiber. The fluorescent properties of the membrane-fiber conjugate have been determined. The membrane is stable, and the pH sensor shows a fast response time and excellent resolution in a wide pH range of 3 to 11.

Biocompatible Materials