Search PubMedSearch

PubMed · 6955321

Nasal support prostheses.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Adams. 1982. Nasal support prostheses.. https://doi.org/10.1016/s0300-5712(82)80006-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of burnout temperature on strength of phosphate-bonded investments.

OBJECTIVE: The high-temperature strength behaviour of dental phosphate-bonded investments is not clearly understood. The present purpose was to determine their variation in strength with temperature and to seek explanations for that variation. METHODS: The clamped-edge disc-rupture test was used in a sequential testing protocol, with a variable casting metal mass, to determine the effect of burnout temperature (ranging from 400 to 1100 degrees C) on the strength of six phosphate-bonded investments. RESULTS: The strength of phosphate-bonded investment is temperature sensitive, generally showing a distinct minimum in the tested temperature range. Low temperature strength gives little information about high temperature behaviour. The variation of strength with temperature seems amenable to explanation in terms of investment composition. CONCLUSION: Since strength varies greatly with temperature and brand, the inconsistency of previous results is explained. On the other hand, low-temperature strength is no guide for the high-temperature strength, so that information on both the room and the service temperature strength is required. Inversion of silica at high temperature may decrease the strength of phosphate-bonded investments.

Chromium Alloys

Corrosion considerations in the brazing repair of cobalt-based partial dentures.

Cobalt-based alloys (Co-Cr-Mo) are usually used in dentistry as frameworks for removable partial dentures. In their basic form these structures function successfully. However, modifications or repairs of the frameworks may reduce their resistance to corrosion and, as a consequence, may provoke biologic reactions in the soft tissues. These reactions may be the result of different types of alloys that contact each other and, in the presence of saliva (based on potential differences), produce a galvanic cell. In this study, a clinical situation after repair of a removable partial denture was examined. The metallographic study of the prosthesis revealed a brazed zone where a gold braze was joining the Co-Cr-Mo framework with a Co-Cr-Ni type alloy (without Mo). The latter revealed signs of corrosion. Various electrochemical parameters (Ecorr, Ecouple, icorr, icouple) of these alloys were analyzed in the laboratory. The Co-Cr-Ni alloy had the lowest nobility and underwent galvanic corrosion in a galvanic couple with gold braze.

Chromium Alloys

Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro.

Titanium is used to fabricate spherical and bar attachments for overdentures on osseointegrated implants. This in vitro study investigated the long-term effects of commercially pure titanium on the retention force of telescope crowns with conical interface. Combinations of various materials for the inner and outer crowns were tested. Telescope crowns of pure titanium showed retention force characteristics comparable to telescope crowns fabricated conventionally in a precious alloy.

Chromium Alloys