Search PubMedSearch

PubMed · 6887602

[192Ir remote afterloading device].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Saegusa, M Kawana, T Mamiya, N Arimizu, S Uematsu, G Uchiyama, H Ikehira. 1983. [192Ir remote afterloading device].. https://pubmed.ncbi.nlm.nih.gov/6887602/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Needle displacement during HDR brachytherapy in the treatment of prostate cancer.

PURPOSE: We used clinical patient data to examine implant displacement between high dose rate (HDR) brachytherapy fractions for prostate cancer to determine its impact on treatment delivery. MATERIALS AND METHODS: We analyzed the verification films taken prior to each fraction for 96 consecutive patients treated with HDR brachytherapy boosts as part of their radiation therapy for definitive treatment of organ-confined prostate cancer at our institution. Patients were treated with 18-24 Gy in 4 fractions of HDR delivered in 40 hours followed by 36-39.6 Gy external beam radiation to the prostate. We determined the mean and maximum displacement distances of marker seeds placed in the prostate and of the implanted needles between HDR fractions. RESULTS: Mean and maximum displacement distances between fractions were documented up to 7.6 mm and 28.5 mm, respectively, for the implant needles and 3.6 mm and 11.4 mm, respectively, for the gold marker seeds. All displacement of implant needles occurred in the caudal direction. At least 1 cm caudal displacement of needles occurred prior to 15.5% all fractions. Manual adjustment of needles was required prior to 15% of fractions, and adjustment of the CLP only was required in 24%. Most of the displacement for both the marker seeds and needles occurred between the first and second fractions. CONCLUSIONS: There is significant caudal displacement of interstitial implant needles between HDR fractions in our prostate cancer patients. Obtaining verification films and making adjustments in the treatment volume prior to each fraction is necessary to avoid significant inaccuracies in treatment delivery.

Brachytherapy

Prostate brachytherapy in patients with prostate volumes >/= 50 cm(3): dosimetic analysis of implant quality.

OBJECTIVES: Permanent implantation with (125)I in patients with localized prostate cancer who have prostate volumes >/= 50 cm(3) is often technically difficult owing to pubic arch interference. The objective of this study was to describe dosimetry outcomes in a group of patients who were implanted using the real-time ultrasound-guided technique who had prostate volumes >/= 50 cm(3). MATERIALS AND METHODS: A total of 331 patients received an (125)I prostate seed implant from January 1, 1995, to June 1, 1999, of whom 66 (20%) had prostate volumes >/= 50 cm(3) at the time of the procedure. The real-time seed implant method was used in all patients and consisted of intraoperative planning and real-time seed placement using a combination of axial and sagittal ultrasound imaging. Pubic arch interference was managed using an extended lithotomy position or by angling the tip of the ultrasound probe in an anterior direction. No preimplant pubic arch CT scan study was performed and no patients were excluded from treatment because of prostate size. Implant quality was assessed using CT-based dosimetry performed 1 month postimplant. Dose-volume histograms for the prostate, bladder, rectum, and urethra volumes were generated. The target dose for these implants was 160 Gy and an adequate implant was defined as the dose delivered to 90% of the prostate (D90) >/= 140 Gy. The dose delivered to 95% of the prostate (D95) and doses to 30% of the rectal (DRECT30) and urethral (DURE30) volumes were also calculated. RESULTS: Prostate volumes in the 66 patients ranged from 50 to 93 cm(3) (median 57, mean 61 cm(3)). Total activity implanted was 27.8-89.1 mCi (median 57 mCi), with a range in activity per seed of 0.36-0.56 mCi (median 0.4 mCi). The prostate D90s and D95s ranged from 13,245 to 22,637 cGy (median 18,750) and 11,856 to 20,853 cGy (median 16,725), respectively. Only one patient (1.5%) had a D90 < 140 Gy. The DURE30 values ranged from 15,014 to 27,800 cGy (median 20,410) and the DRECT30 values were 3137-9910 cGy (median 5515). CONCLUSION: Implantation of the large prostate can be accomplished using the real-time method. A total of 98.5% of the patients receive a high-quality implant. In addition, these implants should not put patients at increased risk for significant urinary and bowel complications because urethral and rectal doses can be kept at acceptable levels.

Brachytherapy

High-dose-rate brachytherapy: dose escalation in three-dimensional miniorgans of the human bronchial wall.

PURPOSE: High-dose-rate (HDR) brachytherapy of human lung cancer is well established, however fractionation schemes and dosages are based mainly on experience. The aim of this investigation was to study the effects of different doses of HDR iridium-192 on normal human bronchial epithelium in three-dimensional miniorgans of the human bronchial wall. METHODS AND MATERIALS: Forty-eight biopsies from normal bronchi were cultivated for 14 days and exposed at random to different doses of HDR iridium 192 (0 Gy, 30 Gy, 45 Gy, 60 Gy, or 75 Gy). Cell viability was assessed immediately after irradiation, after 4 or 18 days by fluorescent staining, and cell damage of the culture was analyzed by light microscopy. Lactate dehydrogenase (LDH) was measured in the supernatant for 4 days. RESULTS: There was no histologically apparent tissue damage regardless of the irradiation dose. The number of nonvital cells increased in irradiated miniorgans depending on the dose used (p < 0. 05 at 75 Gy). This effect occurred early and was less pronounced with time. LDH measurements showed an increase only in the first 24 hours. CONCLUSIONS: Our results confirm that normal bronchial epithelium has a high tolerance to early epithelial damage by irradiation. This model of human bronchial miniorgans is useful for further studies of the effects of irradiation on human bronchi.

Brachytherapy