PubMed · 6853222

A microscope-based flow cytophotometer.

Abstract

By means of a new flow chamber, a standard fluorescence microscope with Epi illumination and 100 W mercury arc excitation has been turned into a flow cytophotometer combining high resolution and sensitivity with simplicity of operation. In the flow chamber, cells are passed in a narrow stream through the microscope focus carried by a laminar flow of water running on the open surface of a cover glass which is coupled to the oil immersion microscope objective. Two spectral components of the fluorescence, for example, resulting from specific staining of two different cellular constituents with different dyes, can be measured simultaneously in separate channels so as to produce three-dimensional histograms. The scattered light of the cells is detected in dark field by a second microscope situated opposite the primary objective. Scattered light detection is integrating with regard to scattering angle from 0 degree to 90 degrees. Hence, diffraction pattern effects are eliminated and the light scatter signal is approximately proportional to cell dry weight. The Epi illumination, which implies that excitation and fluorescence collection are parfocal, greatly simplifies instrument adjustment, which is further facilitated by the fact that the cell stream can be viewed at high magnification. Cell measuring time is about 3 microseconds which implies a measuring rate of 3 x 10(3) cells/s at 1% coincidence rate. Sensitivity is sufficient for measuring the DNA content of bacteria (that is, approximately 5 x 10(-15) g/cell) with a coefficient of variance (CV) of about 6%. CV less than 1% is achieved for DNA histograms of mammalian cells. A 5 W argon laser as excitation source facilitates slit scan analysis and increases the sensitivity and measuring rate by one to two orders of magnitude.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H B Steen. 1983. A microscope-based flow cytophotometer.. https://doi.org/10.1007/bf01042283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

HLA-B27 screening by flow cytometry.

A flow cytometric assay for lymphocyte HLA-B27 expression using a two-color direct immunofluorescent assay was compared to traditional microlymphocytotoxicity testing on 209 clinical samples. For the flow cytometric assay, whole blood was mixed with a monoclonal anti-B27 conjugated to fluorescein-isothiocyanate (FITC) and anti-CD3 conjugated to phycoerythrin (PE). The samples were analyzed with flow cytometry by gating on CD3 positive events and anti-B27 staining intensity was evaluated as median channel fluorescence of the histogram peak. The median channel fluorescence was least with B27 negative and B7 negative samples (84 +/- 17), intermediate with samples that were B27 negative but B7 positive (118 +/- 13), and greatest with samples that were B27 positive (155 +/- 13). In addition to cross-reactivity with the B7 antigen (n = 38), the monoclonal anti-B27 cross-reacted with HLA-B37 positive samples (n = 3) and HLA-B39 positive samples (n = 3). Using a median channel fluorescence cutoff of 136, 39 of the 40 B27 positive samples gave positive results in the flow cytometric assay for a sensitivity of 97.6%. The specificity was 95.9% with 7 false positives of 169 B27 negative samples. The flow cytometric HLA-B27 assay is a convenient, useful screening test. For greatest specificity, samples positive by flow cytometry should be confirmed by conventional microlymphocytotoxicity or by use of other monoclonal antibodies directed against B27.

Flow Cytometry

Flow cytofluorometric detection of inflammatory processes by measuring respiratory burst reaction of peripheral blood neutrophils.

This report describes a method for measuring the respiratory burst in neutrophils, based on intracellular oxidation of the reduced ethidium bromide derivative, hydroethidine. Fluorescence of the resultant product quantitatively determined by flow cytofluorometry serves as a measure of the neutrophil ability to generate superoxide radicals. We found that during inflammation some polymorphonuclear leukocytes showed a considerably lower respiratory burst response to phorbol myristate acetate treatment. It was demonstrated that variations in this parameter could be an indicator of the course of inflammation.

Flow Cytometry