Scatter dose decrement values for rectangular fields.

Abstract

The scatter dose decrement value (SDV) has been studied by calculational methods for 60Co gamma and 4- and 8-MV x-ray beams of rectangular cross section. In a principal plane and inside the field, the SDV is nearly independent of field size, energy, and depth when the position of the point considered is expressed as the fractional distance to the field edge. From this, it follows that the scatter dose profiles are quite similar in planes parallel to a principal plane. A second corollary is that the SDV for an arbitrary point approximately equals the product of the two SDV values for the projected points in the principal planes. Outside the field, the SDV loses this independence of the various beam conditions, and as a consequence thereof, the "product rule" leads to errors. Mathematical expressions have been derived for the SDV inside and outside small fields. The errors resulting when these small-field formulas are used for large fields have been studied. Expressed as fractions of the total dose on the centerline, these errors are of the order of +/- 1% inside the field and +/- 2% outside.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B E Bjärngard, L H Brown, G K Svensson. Scatter dose decrement values for rectangular fields.. https://doi.org/10.1118/1.595191

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

TLD postal dose intercomparison for megavoltage units in Poland.

The aim of the TLD pilot study was to investigate and to reduce the uncertainties involved in the measurements of absorbed dose and to improve the consistency in dose determination in the regional radiotherapy centres in Poland. The intercomparison was organized by the SSDL. It covered absorbed dose measurements under reference conditions for Co-60, high energy X-rays and electron beams. LiF powder type MT-N was used for the irradiations and read with the Harshaw TLD reader model 2000B/2000C. The TLD system was set up and an analysis of the factors influencing the accuracy of absorbed dose measurements with TL-detectors was performed to evaluate and minimize the measurement uncertainty. A fading not exceeding 2% in 12 weeks was found. The relative energy correction factor did not exceed 3% for X-rays in the range 4-15 MV, and 4% for electron beams between 6 and 20 MeV. A total of 34 beams was checked. Deviation of +/- 3.5% stated and evaluated dose was considered acceptable for photons and +/- 5% for electron beams. The results for Co-60, high energy X-rays and electron beams showed that there were two, three and no centres, respectively, beyond acceptance levels. The sources of errors for all deviations out of this range were thoroughly investigated, discussed and corrected, however two deviations remained unexplained. The pilot study resulted in an improvement of the accuracy and consistency of dosimetry in Poland.

Cobalt Radioisotopes

A comparison of surface doses for two immobilizing systems.

To achieve accurate and reproducible treatments, many types of immobilizing systems have been used. Two of these systems: Alpha Cradle and VacFix, conform around the patient to improve day-to-day treatment repositioning. The Alpha Cradle system has been in clinical use for several years. The system involves two polyurethane chemicals which upon mixing in a latex bag will expand and harden around the patient. The second system (VacFix) uses a 0.15 mm thick plastic bag loosely filled with 1 mm polysterol spheres. The patient lays on the bag in the treatment position and the air is evacuated from the bag. This system retains its shape for the entire treatment and can be re-used. In some patient set-ups, it is possible that the beam is modified as it passes through these devices, causing a potential change in the target dose and an increase in the patient surface dose. CT scans of the Alpha Cradle and VacFix systems were performed and relative densities were calculated and compared to air. Material densities and surface dose data for a Cobalt-60 teletherapy unit and a dual photon linear accelerator are presented.

Cobalt Radioisotopes

Experimental determination of the beam quality dependence factors, kQ, for ionization chambers used in photon and electron dosimetry.

Dosimetry in radiotherapy with ionization chambers calibrated in 60Co gamma beams in terms of absorbed dose to water, DW, can be performed if a factor conventionally denoted as kQ is known. The factor kQ depends on the beam quality and the chamber characteristics. Calculated values of the kQ factors for many types of ionization chamber have been recently published. In this work the experimental determination of the kQ factors for various ionization chambers was performed for 6 MV and 15 MV photon beams and for a 14 MeV electron beam. The kQ factors were determined by a procedure based on relative measurements performed with the ionization chamber and ferrous sulphate solution in 60Co gamma radiation and accelerator beams, respectively. The experimental kQ values are compared with the calculated values so far published. Theoretical and experimental kQ values are in fairly good agreement. The uncertainty in the experimental kQ factors determined in this work is less than about 1%, that is, appreciably smaller than the uncertainty of about 1.5% reported for the calculated values.

Cobalt Radioisotopes