Evaluating Doppler devices using a moving string test target.

Abstract

Two moving string test targets have been developed and used to characterize ultrasound Doppler instrumentation. The characteristics investigated were sample volume size and location in space, amplitude sensitivity to Doppler shift, and resolution of Doppler direction. The tests were performed on a combined echo/Doppler instrument and on an annular array system. The procedures can be carried out routinely in the clinical laboratory to ensure that the instrument is working properly or as an aid for correct interpretation of acquired data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A R Walker, D J Phillips, J E Powers. 1982. Evaluating Doppler devices using a moving string test target.. https://doi.org/10.1002/jcu.1870100106

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lung sounds in neonates with and without an added dead space.

Previous studies have reported great difficulty in recording lung sounds from neonates and have found conflicting results. We studied lung sounds in neonates during the inspiratory phase of the respiratory cycle as monitored by inductive plethysmography (A) and by a pneumotachograph and a face mask (B) which added a dead space of 12 mL. Sixteen term babies were tested 12 hr to 6 days (median 45 hours) after birth. Lung sounds were recorded and then analysed using overlapping and non-overlapping fast Fourier transforms. The two methods of analysis showed a difference in intensity but not in frequency. Fourteen babies provided enough breaths for comparison; a total of 596 inspirations were analysed. The intensity of lung sounds on occasion B was higher in all but two babies with a mean B/A ratio of 2.4. The mean (SD) power on occasions A and B was 13.9 (8.5) mW and 26.9 (21.0) mW, P = 0.02, respectively. In all but 4 babies the B/A ratios of the median (f50) and 90th centile (f90) frequencies were scattered randomly within 20% of unity. The mean (SD) f50 on occasions A and B was 205.5 (51.1) Hz and 225.8 (32.3) Hz, P = 0.10, respectively; the mean f90 was 370.3 (91.0) Hz and 396.1 (67.8) Hz, P = 0.25, respectively. Linear regression showed that there is a third-order polynomial relationship between sound intensity and air flow at the mouth. A weaker positive association exists between frequency and air flow, showing that the median and 90th centile frequencies approach an asymptote as flow increases.(ABSTRACT TRUNCATED AT 250 WORDS)

Auscultation

Percussion and physical diagnosis: separating myth from science.

There are three percussion sounds, which are easily distinguishable by objective measures: tympany (heard with percussion over the intestines), resonance (heard over the normal lung), and dullness (heard over the liver or thigh). The percussion sound that is produced reflects the ease with which the body wall vibrates, which in turn is influenced by many variables, including the strength of the stroke, the condition and state of the body wall, and the underlying organs. Underlying organs or disease may cause dullness to occur at distant sites. There is good interobserver agreement among clinicians with regard to calling a particular percussion sound dull, resonant, or hyperresonant. In contrast, there is very poor interobserver agreement among clinicians using percussion to measure the span of a particular organ. The use of comparative percussion can detect most large pleural effusions, but this method is able to detect only a few pneumonias. Shifting dullness is a reliable and fairly accurate sign for the detection of ascites. Both of these techniques can still be recommended after a review of the literature. Topographic percussion (e.g., using percussion to locate the heart, liver, and spleen borders or dimensions) has poor reproducibility, is significantly inaccurate in many patients, and has little clinical utility; it should be abandoned. Its fundamental principle--that sound waves penetrate only several centimeters of tissue, resulting in a note reflecting abnormalities only in this layer of tissue--is incorrect. Auscultatory percussion offers no advantage over conventional percussion, with the possible exception of auscultatory percussion of the shoulder. Auscultatory percussion should be abandoned as a bedside diagnostic technique.

Auscultation