Search PubMedSearch

PubMed · 6764876

[Fixed prosthetics using posts and thimbles].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Ganzo. 1982. [Fixed prosthetics using posts and thimbles].. https://pubmed.ncbi.nlm.nih.gov/6764876/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

O-ring coping attachments for removable partial dentures.

Clinical experiences for the past 9 years have demonstrated the practicability of the O-ring coping attachment, a modification of the telescopic crown-and-sleeve coping retainers, for removable partial dentures. A circumferential groove placed in the primary coping receives an elastomeric O-ring that fits into a corresponding groove made in the internal surface of the telescopic crown. The O-ring not only provides controllable retention but also acts as a shock absorber. Long-term retention of the prostheses can be easily maintained by periodic replacements of the O-rings. Sophisticated procedures and expensive machines are not required to make the prostheses. Excellent patient acceptance and the versatility in clinical applications make this system one of the winning designs for removable partial prosthodontics.

Crowns

In vitro investigation of various attachments for overdentures on osseointegrated implants.

Primary splinting of fixtures with bar attachments has proved to be clinically effective for overdentures on osseointegrated implants in the edentulous mandible. However, in vitro investigations indicate that a more favourable force transfer to the individual fixtures can be attained by secondary splinting of four implants with conical double crowns. This observation could be confirmed in the present study by measurement of implant deflection in a model of the mandible by means of interferometric optical holography. Telescope crowns with conical interface brought about functionally more even movement characteristics of the implants compared to rigid or jointed bar attachments. Moreover, the conical double crowns always ensured a stable position of the denture in contrast to jointed attachments. These results underscore the need to test conical double crowns clinically as anchors for overdentures on osseointegrated implants.

Crowns

Occlusal reconstruction with implant crown pair prostheses. Case report.

Occlusal reconstruction of both arches was performed using splinted implant crown pairs. Each pair of crowns was luted to parallel implant abutment pairs and these were screwed and glued into approximately parallel pairs of implant bodies. Paralleling of holes for implant body pairs was performed using a precision guiding device.

Crowns