Search PubMed⌕ Search

PubMed · 6759469

[Combination osteosyntheses].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Gotzen, N Haas. 1982. [Combination osteosyntheses].. https://pubmed.ncbi.nlm.nih.gov/6759469/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dynamic cervical plates: biomechanical evaluation of load sharing and stiffness.

STUDY DESIGN: An in vitro biomechanical study using a simulated cervical corpectomy model to compare the load-sharing properties and stiffnesses of two static and two dynamic cervical plates. OBJECTIVES: To evaluate the load-sharing properties of the instrumentation with a full-length graft and with 10% graft subsidence and to measure the stiffness of the instrumentation systems about the axes of flexion-extension, lateral bending, and axial torsion under these same conditions. SUMMARY OF BACKGROUND DATA: No published reports comparing conventional and dynamic cervical plates exist. METHODS: Six specimens of each of the four plate types were mounted on ultra-high molecular weight polyethylene-simulated vertebral bodies. A custom four-axis spine simulator applied pure flexion-extension, lateral bending, and axial torsion moments under a constant 50 N axial compressive load. Load sharing was calculated through a range of applied axial loads up to 120 N. The stiffness of each construct was calculated in response to +/-2.5 Nm moments about each axis of rotation with a full-length graft, a 10% shortened graft, and no graft. ANOVA and Fisher's post hoc test were used to determine statistical significance (alpha < or = 0.05). RESULTS: The two locked cervical plates (CSLP and Orion) and the ABC dynamic plate were similar in flexion-extension, lateral bending, and torsional stiffness. The DOC dynamic plate was consistently less stiff. The Orion plate load shared significantly less than the other three plates with a full graft. Both the ABC and the DOC plates were able to load share with a shortened graft, whereas the conventional plates were not. CONCLUSIONS: All plates tested effectively load share with a full-length graft, whereas the two dynamic cervical plates tested load share more effectively than the locked plates with simulated graft subsidence. The effect of dynamization on stiffness is dependent on plate design.

Bone Plates↗

A new anterior cervical instrumentation system combining an intradiscal cage with an integrated plate: an early technical report.

STUDY DESIGN: To provide a technical report on a new device. Early outcome assessment of patients undergoing anterior cervical decompression and stabilization with the described technique. OBJECTIVES: To detail the operative and technical aspects of the new anterior cervical instrumentation and to identify its suitability for an extensive clinical study. SUMMARY OF BACKGROUND DATA: The controversy over the need for fusion in the surgery of cervical disc disease is in part fueled by the absence of an ideal technique. However, the design of the integrated anterior cervical plate and cage device (PCB) appears to provide immediate stability and to restore disc height and cervical lordosis in addition to reducing graft recipient and donor site-related complications. METHODS: After a standard anterior cervical discectomy and preparation of the disc space, the correct size of the cage with integrated plate is inserted. Self-tapping screws are inserted without image intensifier. Cancellous bone chips are used. The technique was used in 29 patients that were followed prospectively from 5 to 24 months (median 8 months, interquartile range 6-15 months). RESULTS: The technique was easy to learn and implement. The authors' experience has been free of intraoperative complications. After surgery no screw backout or device failure was identified. Twenty-seven patients improved clinically. Donor site morbidity was trivial. No collars were applied after surgery. CONCLUSIONS: The design of the system appears to prevent bone-graft recipient site and donor site complications, provides immediate biomechanical stability, prevents screw backout or breakage, and restores posterior interbody height and lordosis. The device is of sufficient promise to warrant further close evaluation focusing on long-term outcome. The new radiolucent version has potential advantages for the assessment of fusion.

Bone Plates↗

Anterior cervical corpectomy and fusion using miniplate and screws in a 7-year-old child with eosinophilic granuloma of the cervical spine.

STUDY DESIGN: This is a case report of a 7-year-old child with eosinophilic granuloma in the cervical spine, which underwent anterior cervical corpectomy and fusion by using Miniplate and screws. OBJECTIVES: To describe the use of Miniplate and screws for pediatric cervical anterior fusion. SUMMARY OF BACKGROUND DATA: Eosinophilic granuloma is a rare disease causing destructive bony lesions of the cervical spine in children. A complete resection and fusion were considered to be the preferable treatment in our case. However, cervical spinal fusion and instrumentation in children may be technically difficult because of the size of the vertebral body and the iliac bone. In addition, a proper device for an internal fixation in pediatric patients is not yet available. METHODS: A case of eosinophilic granuloma in pediatric spine was presented. RESULTS: We confirmed successful bony fusion and the restoration of the normal cervical curvature without recurrence of the tumor 2 years after the procedure. CONCLUSIONS: For proper internal fixation and prevention of dislodgement of the grafted bone, we used the Miniplate and screws as internal fixator after intralesional resection of the tumor mass.

Bone Plates↗