PubMed · 6731685

Intraaortic balloon counterpulsation.

Abstract

The physiologic principle of hemodynamic circulatory support for the failing left ventricle must be directed toward reducing left ventricular work and myocardial oxygen demand and increasing myocardial oxygen supply. This support can best be accomplished with the use of intraaortic balloon counterpulsation. Support of the failing heart after cardiopulmonary bypass was the most frequent indication for counterpulsation treatment in our reported series. This type of assist was required in 5.2 percent of my patients. I reviewed the reports from three medical centers and added our own results in patients who required intraaortic balloon counterpulsation for weaning from cardiopulmonary bypass. Of a total of 399 patients, 255 or 73 percent were weaned off the balloon assist device and of this group, 239 or 60 percent were subsequently discharged from the hospital. Among patients who required intraaortic balloon counterpulsation for postoperative pump failure, 43 (70 percent) of 66 patients were weaned off the intraaortic balloon device, and 35 (53 percent) were later discharged from the hospital. A 24 percent survival rate occurred in patients with cardiogenic shock treated solely with counterpulsation; however, the survival rate increased to 52 percent when those patients subsequently received cardiac catheterization and appropriate surgical intervention.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Kafrouni. 1984. Intraaortic balloon counterpulsation.. https://doi.org/10.1016/0002-9610(84)90189-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory.

Ventricular tachycardia (VT) in the setting of structural heart disease is challenging to treat with percutaneous catheter ablation due to the presence of complex substrate, multiple morphologies, hemodynamic instability, and epicardial circuits. When substrate-based approaches fail, however, it may be impossible to map and ablate hemodynamically unstable arrhythmias. We describe a novel approach to endocardial and epicardial mapping and ablation of hypotensive VT using a percutaneous left ventricular assist device in the electrophysiology laboratory, permitting near-surgical access to cardiac structures.

Assisted Circulation↗

IgG classification of anti-PF4/heparin antibodies to identify patients with heparin-induced thrombocytopenia during mechanical circulatory support.

Commercial immunoassays frequently detect anti-PF4/heparin antibodies during mechanical circulatory support (MCS), but only a small minority of patients develops heparin-induced thrombocytopenia (HIT). Whereas platelet functional tests can distinguish between platelet-activating and non-platelet-activating antibodies, commercial PF4-dependent immunoassays do not. Between 2003 and 2004, 113 patients were placed on MCS. Blood samples were obtained on postimplant day 5-7 for analyses by antibody assays and the functional heparin-induced platelet activation (HIPA) assay. Three distinct groups of patient sera were identified: platelet-activating anti-PF4/heparin antibodies (n = 10), non-platelet-activating anti-PF4/heparin antibodies (n = 53), and anti-PF4/heparin antibody negative (n = 50). Patients with platelet-activating antibodies had the highest risk for thromboembolic events (P < 0.005), whereas those with non-platelet-activating antibodies did not differ from antibody negative patients (P = 0.369). The enzyme-immunoassay and column agglutination assays, which cover all immunoglobulin classes, demonstrated adequate sensitivity and negative predictive value; yet, both lacked specificity with respect to the platelet-activating antibodies. If all antibody positive patients were further classified by an IgG-specific anti-PF4/heparin enzyme-immuno assay, specificity for platelet-activating antibodies increased. Whereas IgG-specific optical density (OD) values below 1.0 were likely for non-platelet-activating anti-PF4/heparin antibodies, higher values were progressively predictive for pathogenic platelet activation. The probability of the development of clinical HIT also increased steeply. In conclusion, platelet-activating anti-PF4/heparin antibodies are relatively common (about 9%) in patients on MCS and are associated with significantly higher thrombotic event rates. Low IgG-specific OD values (< 1.0) in the enzyme-immunoassay indicate low likelihood for the presence of platelet-activating antibodies. These results justify further validation so that anticoagulation during MCS becomes safer and adequate.

Assisted Circulation↗