Search PubMed⌕ Search

PubMed · 6726413

The false fontanel.

Abstract

In the neonate, palpation of the anterior fontanel is recognized as a simple and reliable means for estimating intracranial pressure. With closure of the fontanel this aspect of the clinical examination is lost. The authors report a series of 15 shunted infants and children in whom a false fontanel was created by making a 2-cm craniectomy in the right parietal region and excising the underlying internal pericranium. This produces a cranial opening which, like the anterior fontanel, can be used for palpation and real-time ultrasound imaging of the brain. By removing the internal pericranium, reossification of the defect is delayed by more than 12 months. Sparing the dura propria avoids the risks of cerebrospinal fluid leak or brain herniation into the cranial window. This procedure is reported to be simple, reliable, and of value in assessing shunt function in hydrocephalic infants and young children. An illustrative case report is presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Harbaugh, R L Saunders. 1984. The false fontanel.. https://doi.org/10.3171/jns.1984.61.1.0071

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fetal surgery for myelomeningocele.

INTRODUCTION: Although in utero treatment of myelomeningocele shows promise in decreasing the morbidity of this disease, the risks to the fetus are significant, and the benefits are unproven. TRIAL: The upcoming trial represents one of the few times that the pediatric neurosurgical community has come together to test a new procedure.

Cerebrospinal Fluid Shunts↗

A critical analysis of 'normal' radionucleotide shuntograms in patients subsequently requiring surgery.

BACKGROUND: Shuntograms are performed when patients present with symptoms suggestive of, but inconclusive for, shunt malfunction, without confirmatory radiological evidence. METHODS: Shuntograms over the past 3.5 years were reviewed. Patient records were reviewed for revision in proximity to a negative (normal) study. RESULTS: One hundred and fifteen out of 149 tests were negative. Thirty-four surgeries (in 31 patients) occurred subsequent to a negative shuntogram. In 18 out of 34 revisions the shunt was functional: 13 surgeries were for overdrainage, 4 were for unrelated reasons with shunt function confirmed incidentally and 1 was an exploration for cognitive deterioration. In 16 cases (13 patients) the shunt was not functional: 12 had proximal catheter occlusion in which, on subsequent review, there was no ventricular reflux present and the remaining had distal malfunctions. CONCLUSIONS: The false negative rate for shuntograms was 16 out of 115 (14%) with proximal occlusion most common. This estimate of the predictive value of a normal flow study may influence the decision to revise a shunt.

Cerebrospinal Fluid Shunts↗

Analysis of CSF shunting procedure requirement in children with posterior fossa tumors.

OBJECT: The authors analyze the factors that predispose to persistent hydrocephalus in children with posterior fossa tumors and compare their results and treatment policy with those described in the literature, particularly with regard to the higher postoperative shunt insertion rates, which have led some authors to the routine use of preoperative third ventriculostomy. METHODS: The clinical records of 180 children treated for posterior fossa tumors in the Department of Pediatric Neurosurgery of the National Institute of Neurosurgery, Budapest, Hungary, between 1990 and 2000 were retrospectively reviewed. CONCLUSIONS: The low postoperative shunt insertion rate in our series (15.5%) led us to believe that the routine use of preoperative third ventriculostomy is not entirely justified. Factors such as patient's age and tumor type, which showed a statistically significant association with the postoperative shunt requirement in our study, should be considered when the decision regarding treatment is made.

Cerebrospinal Fluid Shunts↗