A novel approach to patient radiation dose reduction in X-ray computed tomography (CT) (variable dose scanning) is proposed and evaluated. This technique spares radiosensitive tissues from unnecessary radiation if they are not in the area of immediate clinical interest. Specifically evaluated is the potential for reduction of dose to the eye and active bone marrow in head transmission CT. Using computer simulations, doses are calculated for an easily implementable two level exposure variation, and results are discussed for the fully optimized case in which the intensities of all pencil beams are independently variable. Dose reductions of more than 80% in peak dose are possible in head scanning. To determine whether the filtered backprojection algorithm is optimal in terms of signal-to-noise ratio of the final images for this novel scanning technique, a Cramer-Rao lower bound to noise in the image (which is independent of reconstruction algorithm) is derived and calculated for several types of scan. The bound uses the photon distributions determined from mathematical optimization and is compared with the actual noise of the reconstructions. The comparison indicates that little if any improvement can be expected in signal-to-noise ratio using reconstruction algorithms other than the filtered backprojection.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Stanton, O Tretiak. 1983. Dose reduction through variable dose CT scanning: optimality of the filtered backprojection algorithm.. https://doi.org/10.1097/00004728-198312000-00021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Soil-to-grain transfer of fallout 90Sr for 28 winter wheat cultivars.

In order to identify wheat cultivars with minimum soil-to-grain transfer of fallout 90Sr, 28 winter wheat cultivars were investigated at three different sites with different soil types in Upper Bavaria. Each cultivar was grown on an area of 10 m2 and harvested in August 1999. Mean soil-to-grain concentration ratios (C(r)) were 0.151 +/- 0.029, 0.205 +/- 0.035 and 0.060 +/- 0.012, respectively. The C(r) values obtained varied by factors of up to 2.6 for the different cultivars at a given site, and by factors of up to 5.0 for the different sites and a given cultivar. Site-averaged normalized concentration ratios (SANC(r)) ranged from 0.666 +/- 0.062 to 1.503 +/- 0.161. The cultivars Convent, Ludwig, and Semper, showed the lowest uptake of (90)Sr compared to the mean of all cultivars at each site. A cultivar that shows both minimum uptake of 90Sr and 137Cs could not be identified. The results suggest that 90Sr rather than 137Cs might be the limiting radionuclide concerning the use of contaminated land for wheat production. Thus, more efforts might be necessary identifying wheat cultivars with minimum 90Sr uptake.

Radiation Dosage↗

Etched tracks and serendipitous dosimetry.

Nuclear tracks in detectors that just happened to be there can be found in unexpected places. Eyeglasses, household glass, minerals, objects that were exposed to nuclear explosions, and space equipment on the moon are examples. Such materials allow us to measure doses of past radon exposures, cosmic-ray fluences, fission rates and neutrons. Incidental results include measuring mountain-building rates and deciding where finding oil is likely (or unlikely); in another case erosion rates of surface materials in space are found. New results that assess the effects of hydration layers on the leaching out from glass surfaces of imbedded alpha-recoil nuclei imply that long-term, retrospective radon measurements can be made more reliable by selecting only glass with compact hydration layers.

Radiation Dosage↗