Dynamic BTPS correction factors for spirometric data.

Abstract

Because it is often difficult to completely control ambient temperature, a study was conducted to investigate dynamic body temperature pressure saturated (BTPS) correction factors for spirometric data. A forced expiratory simulator system was heated to 37 degrees C and loaded with air saturated with water vapor. This air was then forced from the simulator into a dry rolling-seal spirometer maintained at various ambient temperatures from 3 to 32 degrees C. Errors in forced expiratory volume in 1 s (FEV1) and peak flow from assuming a constant BTPS correction ranged from 7.7 and 14.1% at 3 degrees C to 2.1 and 4.6% at 23 degrees C. Differences between errors observed when saturated and dry air were forced into the spirometer indicate that water vapor condensation introduces an added heat load to the spirometer, adding approximately one percent to the error in FEV1 at lower temperatures. By use of a model to estimate the dynamic BTPS correction factor, errors in FEV1 at all temperatures between 3 and 32 degrees C were reduced to less than 1.5%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J L Hankinson, J O Viola. 1983. Dynamic BTPS correction factors for spirometric data.. https://doi.org/10.1152/jappl.1983.55.4.1354

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of ultrafiltration on thermal variables, skin temperature, skin blood flow, and energy expenditure during ultrapure hemodialysis.

The cause of the increase in core temperature (CT) during hemodialysis (HD) is still under debate. It has been suggested that peripheral vasoconstriction as a result of hypovolemia, leading to a reduced dissipation of heat from the skin, is the main cause of this increase in CT. If so, then it would be expected that extracorporeal heat flow (Jex) needed to maintain a stable CT (isothermic; T-control = 0, no change in CT) is largely different between body temperature control HD combined with ultrafiltration (UF) and body temperature control HD without UF (isovolemic). Consequently, significant differences in DeltaCT would be expected between isovolemic HD and HD combined with UF at zero Jex (thermoneutral; E-control = 0, no supply or removal of thermal energy to and from the extracorporeal circulation). During the latter treatment, the CT is expected to increase. In this study, changes in thermal variables (CT and Jex), skin blood flow, energy expenditure, and cytokines (TNF-alpha, IL-1 receptor antagonist, and IL-6) were compared in 13 patients, each undergoing body temperature control (T-control = 0) HD without and with UF and energy-neutral (E-control = 0) HD without and with UF. CT increased equally during energy-neutral treatments, with (0.32 +/- 0.16 degrees C; P = 0.000) and without (0.27 +/- 0.29 degrees C; P = 0.006) UF. In body temperature control treatments, the relationship between Jex and UF tended to be significant (r = -0.51; P = 0.07); however, there was no significant difference in cooling requirements regardless of whether treatments were done without (-17.9 +/- 9.3W) or with UF (-17.8 +/- 13.27W). Changes in energy expenditure did not differ among the four treatment modes. There were no significant differences in pre- and postdialysis levels of cytokines within or between treatments. Although fluid removal has an effect on thermal variables, no single mechanism seems to be responsible for the increased heat accumulation during HD.

Body Temperature↗

Finite volume analysis of temperature effects induced by active MRI implants with cylindrical symmetry: 1. Properly working devices.

BACKGROUND: Active Magnetic Resonance Imaging implants are constructed as resonators tuned to the Larmor frequency of a magnetic resonance system with a specific field strength. The resonating circuit may be embedded into or added to the normal metallic implant structure. The resonators build inductively coupled wireless transmit and receive coils and can amplify the signal, normally decreased by eddy currents, inside metallic structures without affecting the rest of the spin ensemble. During magnetic resonance imaging the resonators generate heat, which is additional to the usual one described by the specific absorption rate. This induces temperature increases of the tissue around the circuit paths and inside the lumen of an active implant and may negatively influence patient safety. METHODS: This investigation provides an overview of the supplementary power absorbed by active implants with a cylindrical geometry, corresponding to vessel implants such as stents, stent grafts or vena cava filters. The knowledge of the overall absorbed power is used in a finite volume analysis to estimate temperature maps around different implant structures inside homogeneous tissue under worst-case assumptions. The "worst-case scenario" assumes thermal heat conduction without blood perfusion inside the tissue around the implant and mostly without any cooling due to blood flow inside vessels. RESULTS: The additional power loss of a resonator is proportional to the volume and the quality factor, as well as the field strength of the MRI system and the specific absorption rate of the applied sequence. For properly working devices the finite volume analysis showed only tolerable heating during MRI investigations in most cases. Only resonators transforming a few hundred mW into heat may reach temperature increases over 5 K. This requires resonators with volumes of several ten cubic centimeters, short inductor circuit paths with only a few 10 cm and a quality factor above ten. Using MR sequences, for which the MRI system manufacturer declares the highest specific absorption rate of 4 W/kg, vascular implants with a realistic construction, size and quality factor do not show temperature increases over a critical value of 5 K. CONCLUSION: The results show dangerous heating for the assumed "worst-case scenario" only for constructions not acceptable for vascular implants. Realistic devices are safe with respect to temperature increases. However, this investigation discusses only properly working devices. Ruptures or partial ruptures of the wires carrying the electric current of the resonance circuits or other defects can set up a power source inside an extremely small volume. The temperature maps around such possible "hot spots" should be analyzed in an additional investigation.

Body Temperature↗