A reference system for ionized calcium.

Abstract

Reference systems in clinical chemistry, whether loosely structured or highly organized like the National Reference System for Clinical Chemistry (NRSCC) in the USA are built upon an assemblage of interrelated materials, methods, and agreements. For example, the NRSCC Council has accepted the following items for the measurement of total calcium in human serum: 1) the Reporting Unit (the SI non-coherent molar concentration unit-mmol/l), 2) a Certified Reference Material (NBS/SRM 915 CaCO3), 3) a Definitive Method (IDMS) and 4) a Reference Method (FAAS). Recently, the IDMS measured calcium value has become available on a freeze-dried human serum (NBS/SRM 909) and allows the direct accessment of the accuracy of routine methods, instrument systems, calibrators and control materials. Utilizing the NRSCC reference method and materials for total calcium measurements and the Radiometer System (ICA1) for ionized Ca2+ measurements, we have begun to ask the question, "What are the essential items in a reference system for ionized calcium?" As expected, our initial explorations reveal more problems than answers, thus our very limited and unsophisticated initial data will be presented primarily as a means to ensure discussion. Despite, the electrochemical complexity of the electrochemical interactions, and the technologic differences from one measuring system to another, it is my belief that a reference system capable of widespread acceptance for ionized Ca2+ must be introduced to ensure the long-term integrity and interlaboratory compatibility of this vital physiological measurement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G N Bowers. 1983. A reference system for ionized calcium.. https://pubmed.ncbi.nlm.nih.gov/6578576/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Integration of data derived from biological variation into the quality management system.

BACKGROUND: [corrected] Data on within- and between-subject biological variation are available for around 250 analytes commonly used in medical laboratories. METHODS: Integration of this data into the quality system occurs at all three levels of laboratory activity: (a) Preanalytic process: biological variation provides the basis for selecting the most appropriate specimen for analysis, for defining sample stability and for deciding suitable timing between samplings; (b) analytic process: biological variation-derived goals are fundamental for designing internal quality control procedures, and for evaluating laboratory performance; and (c) postanalytic process: delta checks based on within-subject biological variation values are used for validating results and for interpreting serial results from a patient. CONCLUSION: The biological variation is a pillar for managing quality in laboratory medicine.

Blood Chemical Analysis↗