Search PubMed⌕ Search

PubMed · 6561255

A new inductive applicator for hyperthermia.

Abstract

We have designed a new type of applicator for inductive heating which consists of a one-turn, square, column-like coil, through which RF current flows. The material to be heated is placed alongside one of the external sides of the coil. The depth of penetration from an applicator with a height of 20 cm, width of 20 cm, depth of 60 cm was calculated to be 11.7 cm. However, in experiments using a muscle-equivalent agar phantom 60 cm X 60 cm X 60 cm, the penetration depth proved to be 9.6 cm; but in another experiment using a smaller phantom 20 cm X 40 cm X 60 cm, the penetration depth was 6.3 cm. This means that the depth of penetration depends not only on the size of the applicator but also on the shape of the material heated. Our study clearly showed that this applicator produces much less heat in the fat layer than in the muscle layer and should be an inductive applicator suitable for deep heating cancer therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Kato, T Ishida. 1983. A new inductive applicator for hyperthermia.. https://doi.org/10.1080/16070658.1983.11689339

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Understanding submucosal electrosurgery for the treatment of nasal turbinate enlargement.

The surgical management of inferior turbinate enlargement is controversial. Submucosal electrosurgical techniques for turbinate reduction include conventional diathermy, radiofrequency tissue reduction and coblation. All electrosurgical techniques use radiofrequency electricity to damage turbinate tissue but differ in the control and delivery of energy. This review will examine the history of submucosal electrosurgery and clarify the various techniques. This review will also examine the evidence for the efficacy and safety of electrosurgery for the treatment of nasal turbinate enlargement, and will make a case that no progress will be made in clinical trials on the safety and efficacy unless there is standardisation of equipment and techniques in nasal electrosurgery.

Diathermy↗

Measurement of the specific heat capacity of liver phantom.

Phantoms are often used to simulate tissue during the development, testing and calibration of medical devices. In order to infer the specific absorption rate (SAR) and resistive heating in phantoms from temperature measurements, the specific heat capacity and density of the phantom are needed. Stauffer et al (2003 Int. J. Hyperth. 19 89-101) developed several phantoms that mimic dielectric properties of liver tissue at 915 MHz. However, thermal properties of the phantoms were not presented. We have measured specific heat capacities and densities for these phantoms. We also present dielectric properties for these phantoms measured from 0.7 to 20 GHz, including 2.45 GHz--a commonly used frequency for microwave hyperthermia and ablation.

Diathermy↗