Search PubMed⌕ Search

PubMed · 6544800

Removable partial denture design: a photoelastic study.

Abstract

Quantifiable frozen-stress photoelastic techniques were used to analyze stresses induced in mandibular models by a conventional free-end saddle removable partial denture. Four quasi-anatomical mandibular models were constructed for processing, together with their respective calibration specimens, through identical time/temperature stress-freezing cycles. After processing and slicing, an unloaded control model demonstrated some low-order fringes adjacent to the coronal third of the abutment tooth roots, but was otherwise stress free. A lower bilateral free-end saddle partial denture was constructed and fitted in turn to each of the remaining three models. Each denture/model combination was then loaded and processed through a stress-freezing cycle. After processing, 6-mm slices were cut from selected regions for analysis for the presence of stresses. Using a polariscope with circular polarized, monochromatic light, values for maximum shear stress were calculated at selected points in the slices taken from the three loaded models. Variations up to 28% of the mean were obtained for the three experimental models as compared with the consistent results for the material fringe values obtained from the calibration specimens. The study pointed out the problems involved in using photoelastic stress analysis on complicated anatomical models. The interpretation of the results from such studies should be approached with caution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B L Stewart, R O Edwards. Removable partial denture design: a photoelastic study.. https://doi.org/10.1002/jbm.820180903

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of the partial denture on the articulation of dental and postalveolar sounds.

Dental prosthesis is a foreign body in oral cavity and thus necessarily interferes with speech articulation. The purpose of this study was to examine influence of partial denture on speech quality and to show eventual differences in pronunciation of dental sounds c[ts], z [z], s [s] and postalveolar sounds c [t], z [3] and s [integral of]. We have examined differences in pronunciation between subjects with removable partial dentures, the same group without partial dentures and a control group. The study was performed on 30 subjects with removable partial dentures and 30 subjects with complete dental arch. All subjects were recorded while reading six Croatian words containing the examined sounds. Recordings were analyzed with Multispeech Program (Kay Elemetrics Inc.). Acoustic analysis--LPC (linear prediction coding) provided formant peaks (Hz) for each examined sound, its intensity (dB) and formant bandwidths (Hz). Results showed that subjects with partial dentures had 50% less distorted variables and that prostheses did not completely restore articulation of postalveolar sounds. Groups with and without prostheses had lower formant peaks intensities and wider formant bandwidths in comparison to the control group. Partial dentures have not significantly interfered with resonance frequency. At the same time, pronunciation of the examined sounds was significantly improved. However, precision of the articulation movements has deteriorated.

Denture, Partial↗