Search PubMed⌕ Search

PubMed · 6503258

Computer-controlled temperature multiplexer for thermal dosimetry studies.

Abstract

Thermistor probes are widely used for mapping thermal distributions in hyperthermia research. To facilitate multi-probe mapping, a computer-controlled multiplexer for automated thermistor impedance measurement and temperature conversion is described. A complete hardware interface schematic is shown. An algorithm which calculates individual temperature values as a function of thermistor impedance is tested. Total error is quantified by calculating the absolute error between the theoretical temperatures obtained from the algorithm and the experimental calibration temperatures obtained from a National Bureau of Standards referenced mercury thermometer. If calibration intervals of 1.00 degree C or less are used, the total error of the system is less than 0.10 degree C.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T P Ryan, R H Britt. 1984. Computer-controlled temperature multiplexer for thermal dosimetry studies.. https://doi.org/10.1016/0141-5425(84)90079-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗