Temperature corrections in routine spirometry.

Abstract

Forced expiratory volume (FEV1) and forced vital capacity (FVC) were measured in nine normal subjects with three Vitalograph and three rolling seal spirometers at three different ambient temperatures (4 degrees C, 22 degrees C, 32 degrees C). When the results obtained with the rolling seal spirometer were converted to BTPS the agreement between measurements in the three environments improved, but when the Vitalograph measurements obtained in the hot and cold rooms were converted an error of up to 13% was introduced. The error was similar whether ambient or spirometer temperatures were used to make the conversion. In an attempt to explain the behaviour of the Vitalograph spirometers the compliance of their bellows was measured at the three temperatures. It was higher at the higher temperature (32 degrees C) and lower at the lower temperature (4 degrees C) than at the normal room temperature. These changes in instrument compliance could account for the differences in measured values between the two types of spirometer. It is concluded that the ATPS-BTPS conversion is valid and necessary for measurements made with rolling seal spirometers, but can cause substantial error if it is used for Vitalograph measurements made under conditions other than normal room temperature.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Cramer, A Peacock, D Denison. 1984. Temperature corrections in routine spirometry.. https://doi.org/10.1136/thx.39.10.771

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Medical and psychologic outcome of living lobar lung transplant donors.

BACKGROUND: Living donor lobar lung transplantation is a viable therapy for carefully selected patients with end-stage pulmonary disease. Its success is largely dependent upon donor outcome, including both physical and emotional factors. To date, there has been little focus on psychosocial outcomes of lobar lung donors. METHODS: Retrospective evaluation of 15 of 20 living lobar lung transplant donors was performed. Donors underwent evaluation of pulmonary function after recovery from donor lobectomy. Participants completed two self-report questionnaires, the SF-36 Health Survey (SF-36) and the Beck Depression Inventory (BDI), as well as an open-ended psychiatric interview. RESULTS: After lobar donation, mean forced expiratory volume in 1 second (FEV(1)) decreased by 21 +/- 2%, forced vital capacity (FVC) decreased by 16 +/- 3%, total lung capacity (TLC) decreased by 15 +/- 3%, and single-breath diffusing capacity (DLCO) decreased by 14 +/- 4%. All subjects scored higher than the national average on both the physical and mental health components of the SF-36. The BDI scores showed no evidence of clinical depression. However, the subjective interviews elicited two common complaints: (1) a decline in exercise performance, not accounted for by resting lung function measurements; and (2) a dissatisfaction with the degree of acknowledgment of their donation. CONCLUSIONS: Living lobar lung transplant donors enjoy generally satisfactory physical and emotional health. Donors report positive feelings about donation, but wish to be recognized and valued by the transplant team and by the recipient. Despite preservation of lung function within the normal range, some donors also experience a subjective decline in exercise tolerance. Long-term medical and psychologic follow-up appears warranted to monitor symptoms of exercise impairment and to enhance the donor experience.

Forced Expiratory Volume↗