Search PubMed⌕ Search

PubMed · 6486548

Method for rapid fluid replacement questioned.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K V Iserson, A K Reeter. 1984. Method for rapid fluid replacement questioned.. https://doi.org/10.1016/s0196-0644(84)80097-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasound protocols used to detect vascular gas emboli in divers: a systematic review.

INTRODUCTION: Venous gas emboli (VGE) detected via ultrasound can be used as a surrogate marker for decompression stress. While Doppler ultrasound is the historical gold standard, two-dimensional (2D) ultrasonography offers advantages for on-site monitoring, including a wider field of view and reduced dependence on noise-free environments. This systematic review evaluates 2D ultrasonography protocols used in decompression research since the 2015 International Meeting on Ultrasound for Diving Research, identifying methodological similarities, differences, and adherence to consensus recommendations. METHODS: A search of PubMed and Scopus identified studies using 2D ultrasound to detect VGE in divers. Inclusion criteria were: (1) use of 2D ultrasound, (2) detection of VGE or monitoring of decompression stress, (3) inclusion of a diver cohort, and (4) publication after 2015. Data extraction focused on VGE scoring systems, ultrasound hardware, measurement protocols, and operator experience. Risk of bias was assessed using ROBINS-I-V2, and compliance with the 2015 consensus recommendations was evaluated. RESULTS: Twenty studies were included. The Eftedal-Brubakk scale was most commonly used (n = 15), with cardiac ultrasound as the primary imaging modality; one study assessed a peripheral vessel. Common shortcomings included post-dive measurements lasting less than two hours, underreporting of operator experience and hardware specifications, limited individual-level data, and inappropriate use of parametric statistics for ordinal bubble grade data. No study fully complied with all consensus recommendations. CONCLUSIONS: This review demonstrates that, although two-dimensional ultrasound is widely used for post-dive VGE assessment, methodological heterogeneity with multiple shortcomings remain. Furthermore, nearly all studies restricted imaging to the heart, thus leaving peripheral vessel assessment largely unexplored.

Embolism, Air↗

Complications of laparoscopy.

The frontiers of laparoscopic surgery have extended from gynecologic procedures to general surgical techniques. As new applications for laparoscopy emerge, anesthesiologists must be familiar with the possible complications associated with the various laparoscopic procedures. Only by an appreciation of the potential complications of a procedure can their overall incidence be minimized. A systematic approach must consider all potential complications during laparoscopy. In addition to routine evaluation (i.e., depth of anesthesia and volume status), anesthesiologists must confirm that intra-abdominal pressure is less than 15 mm Hg, and that inadvertent endobronchial intubation, pneumothorax, and gas embolism have not occurred. In the case of precipitous changes in vital signs not responding to routine management, it is imperative to release the pneumoperitoneum and place the patient in the supine (or Trendelenburg) position. After cardiopulmonary stabilization, cautious slow reinsufflation then can be attempted. With persistent signs of significant cardiopulmonary impairment, however, it is sometimes necessary to convert to an open procedure.

Embolism, Air↗

[A case of suspected pulmonary air embolism in endoscopic neurosurgery].

Sudden reduction in end-tidal PCO2 and SpO2 occurred during the endoscopic third ventriculostomy in a patient with hydrocephalus under general anesthesia. We suspect that it was caused by pulmonary air embolism. A 63-year-old female was scheduled for endoscopic third ventriculostomy under general anesthesia. Endoscopic manipulation caused hemorrhage from chorioid plexus 21 minutes after the procedure was begun, and intraventricular irrigation was performed to achieve hemostasis. In the subsequent 3 minutes, end-tidal PCO2 declined from 26 mmHg to 15 mmHg (PaCO2 39.6 mmHg), and SpO2 declined from 98% to 92% (PaO2 69.2 mmHg). Nitrous oxide was discontinued immediately because pulmonary air embolism was suspected and the oxygen concentration was increased to 100%. At the same time the surgical procedure was discontinued. After 15 minutes, end-tidal PCO2 recovered to 25 mmHg, and SpO2 recovered to 98% (PaO2 136.5 mmHg), and surgery was resumed. The patient recovered from anesthesia. The chest X-p at the end of operation, and pulmonary scintigraphy on the following day revealed no abnormal findings, but brain CT demonstrated a large quantity of air in both lateral ventricles.

Embolism, Air↗