Search PubMed⌕ Search

PubMed · 6448232

[Problems in the demonstration immune complexes].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H H Sedlacek, W Pernice, F R Seiler. 1980. [Problems in the demonstration immune complexes].. https://pubmed.ncbi.nlm.nih.gov/6448232/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Oxidized LDL immune complexes induce release of sphingosine kinase in human U937 monocytic cells.

The transformation of macrophages into foam cells is a critical event in the development of atherosclerosis. The most studied aspect of this process is the uptake of modified LDL through the scavenger receptors. Another salient aspect is the effect of modified LDL immune complexes on macrophages activation and foam cell formation. Macrophages internalize oxidized LDL immune complexes (oxLDL-IC) via the Fc-gamma receptor and transform into activated foam cells. In this study we examined the effect of oxLDL-IC on sphingosine kinase 1 (SK1), an enzyme implicated in mediating pro-survival and inflammatory responses through the generation of the signaling molecule sphingosine-1-phosphate (S1P). Intriguingly, oxLDL-IC, but not oxLDL alone, induced an immediate translocation and release of SK1 into the conditioned medium as evidenced by fluorescence confocal microscopy. Immunoblot analysis of cell lysates and conditioned medium revealed a decrease in intracellular SK1 protein levels accompanied by a concomitant increase in extracellular SK1 levels. Furthermore, measurement of S1P formation showed that the activity of cell-associated SK decreased in response to oxLDL-IC compared to oxLDL alone, whereas the activity of SK increased extracellularly. Blocking oxLDL-IC binding to Fc-gamma receptors resulted in decreased levels of extracellular S1P. The data also show that cell survival of human U937 cells exposed to oxLDL-IC increased compared to oxLDL alone. Exogenously added S1P further increased cell survival induced by oxLDL-IC. Taken together, these findings indicate that S1P may be generated extracellularly in response to modified LDL immune complexes and may therefore promote cell survival and prolong cytokine release by activated macrophages.

Antigen-Antibody Complex↗

A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7.

The sensitivity and specificity of a polyethylene glycol terminated alkanethiol mixed self-assembled monolayers (SAM) on surface plasmon resonance (SPR) immunosensor to detect Escherichia coli O157:H7 is demonstrated. Purified monoclonal (Mabs) or polyclonal antibodies (PAbs) against E. coli O157:H7 were immobilized on an activated sensor chip and direct and sandwich assays were carried to detect E. coli O157:H7. Effect of Protein G based detection and effect of concentrations of primary and secondary antibodies in sandwich assay were investigated. The sensor surface was observed under an optical microscope at various stages of the detection process. The sensor could detect as low as 10(3)CFU/ml of E. coli O157:H7 in a sandwich assay, with high specificity against Salmonella Enteritidis. The detection limit using direct assay and Protein G were 10(6)CFU/ml and 10(4)CFU/ml, respectively. Results indicate that an alkanethiol SAM based SPR biosensor has the potential for rapid and specific detection of E. coli O157:H7, using a sandwich assay.

Antigen-Antibody Complex↗

Uncoated, broad fluorescent, and size-homogeneous CdSe quantum dots for bioanalyses.

In the present study, we describe the synthesis of highly luminescent uncoated water-soluble CdSe quantum dots (QDs) possessing the following characteristics: approximately 2 nm in diameter, with very good size distribution (in 95% homodispersed) accompanied by a broad-band photoluminescent spectrum. The synthetic procedure is simple, is conducted at room temperature, in the absence of the most popular coordinating ligands (as TOPO or HDA), and is highly reproducible. The obtained CdSe core QDs possessed a comparatively long fluorescence half-life (approximately 30-90 ns, depending on the emission wavelength) detected by time-resolved spectroscopy. These QDs were further conjugated with antibodies and applied in several biochemical analyses.

Antigen-Antibody Complex↗