Search PubMed⌕ Search

PubMed · 6419587

More efficient system for preparing total parenteral nutrient solutions.

Abstract

An improved system for preparing total parenteral nutrient (TPN) solutions is described. The new system uses a personal computer, a three-station volumetric pump, and empty polyvinyl chloride (PVC) containers. The computer's order-entry screen facilitates data entry by displaying a format similar to the physician's order sheet. After calculating the volumes of i.v. solutions and additives and the total cost of the TPN solution, the computer prints labels containing this information. Using the volumetric pump, the required volumes of crystalline amino acids, dextrose injection, and sterile water for injection are added simultaneously to either one-liter or three-liter PVC containers. Each bag contains the patient's entire daily TPN requirements. Approximately 30 liters of TPN solution are prepared daily by specially trained technicians in a centralized i.v. room. Compared with the previous method of preparing TPN solutions using evacuated one-liter glass bottles, the average time required to prepare and determine the cost of each patient's TPN solutions has decreased from 35 to 21 minutes daily. Total savings resulting from reduced materials and labor costs is approximately $28,240 annually. The new system for preparing TPN solutions is efficient and cost effective.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Condella, R J Baptista, R E Griffin. 1983. More efficient system for preparing total parenteral nutrient solutions.. https://pubmed.ncbi.nlm.nih.gov/6419587/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A correction factor for bridging compaction simulator and different roller compactors.

Roller compaction (RC) is an important dry granulation technique. Since pilot and commercial scale roller compactors, which operate continuously on a large scale, usually require kilograms of material per run, formulation and process development directly on such roller compactors is not practical. In contrast, a compaction simulator (CS) can produce ribblets, also known as "slugs", using only a few grams of material with sinusoidal displacement profile replicating the motion of a specific point on the roll surface. Thus, it is possible to develop RC formulation and process in laboratory using a CS-based material-sparing approach. However, because of the inherently different configurations for applying pressure between die compression and roll compression, translating uniaxial pressure from CS experiments to roll pressure during RC is often unreliable, leading to significant uncertainties in the critical quality attributes of ribbons, such as ribbon solid fraction (or porosity) and mechanical strength. The objective of this study was to identify a correction factor (Kp = uniaxial die compression pressure/roll pressure), by correlating the compressibility profiles from CS and a roller compactor of interest, to enable more reliable process translation from CS to roller compactor. In this study, a Kp value of 0.5 was determined for Alexanderwerk WP120 and validated for Gerteis Mini-Pactor and Bepex Pharmapactor. This value may serve as a starting point for translating the optimal compaction pressure identified based on CS investigation to common roller compactors, requiring only minor adjustments to attain optimal RC process parameters (i.e., roll force and roll gap) for a chosen roller compactor.

Drug Compounding↗

Establishing a stability window for medium- and long-chain-triglyceride lipid-based total nutrient admixtures using USP standards.

PURPOSE: The stability window of medium-chain triglyceride (MCT) and long-chain-triglyceride (LCT) lipid-based total nutrient admixtures (TNAs) was studied. METHODS: Sixteen different admixtures were selected for study. Of these, eight base macronutrient concentrations representing low and high concentrations were selected, along with low and high concentrations of electrolytes. All TNAs studied contained 2 mg of elemental iron as part of the trace-element formulation, an amount previously shown to produce unstable TNAs with pure LCT-based lipid injectable emulsions. All admixtures were prepared in triplicate and analyzed over five time intervals: time 1 (immediately after preparation), time 2 (after four days of storage at 6 +/- 2 degrees C), and times 3, 4, and 5, corresponding to 6, 24, and 30 hours of storage at 25 +/- 2 degrees C, respectively, after time 2. Stability was measured by comparing results with USP standards for fat globule size in lipid injectable emulsions. RESULTS: A total of 48 admixtures were studied. Samples at each time interval showed an inconsistent but general increase in the number of globules with a diameter of >1.8 microm over time. All admixtures met both the proposed pharmacopoeial criteria for stability with respect to mean droplet size and volume-weighted proportion of fat globules with a diameter of >5 microm. CONCLUSION: A wide range of macronutrients and micronutrients were tested in a series of MCT-LCT-based TNAs and found to be stable. The use of MCTs and LCTs in lipid injectable emulsions confers greater stability to TNAs than has been achieved with pure LCT-based formulations.

Drug Compounding↗