"Staying power"--absorbable vs. nonabsorbable.

Abstract

An experiment was designed to compare the "holding power" or "staying power" of absorbable (polyglycolic acid and polyglactin 910) and nonabsorbable (nylon) suture. The aim of this experiment was to determine what provides the lasting strength of the bond between soft tissues that are approximated or plicated. When correcting the rectus diastasis during abdominoplasty, we used nylon sutures in 15 patients and absorbable synthetic sutures in 15 other patients. We then marked the closed folds of the rectus sheath with small metal vascular clips. Two days later and approximately 6 months after operation an upright anteroposterior abdominal x-ray was taken and the position of the metal clips was compared in the test groups. Although there was usually slight separation of the clips after 6 months, no significant difference between the two groups was noted, thereby indicating that holding power is not related to type of suture material but more likely to fibroplasia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D C Birdsell, G E Gavelin, G M Kemsley, K S Hein. 1981. "Staying power"--absorbable vs. nonabsorbable.. https://doi.org/10.1097/00006534-198111000-00013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Abdominal muscle flap repair for large defects of the diaphragm.

Repair of a large diaphragmatic defect in congenital diaphragmatic hernia (CDH) and eventration of the diaphragm (DE) is difficult, especially when this is an unexpected finding at surgery. A patch of synthetic material may not be available at short notice, especially in developing countries. We describe the repair of nine such defects by using an abdominal muscle flap comprising the transversus abdominis and internal oblique muscles based on the intercostal and subcostal vessels. Although reports of similar flap repairs have been published in the literature [1-5], these employed a subcostal incision for abdominal entry, which we believe jeopardizes the flap's vascularity. Thus, we prefer to use an upper abdominal midline incision for abdominal entry in all cases of CDH and DE.

Abdominal Muscles↗

The response of the transverse abdominis and internal oblique muscles to different postures.

The purpose of this study was to consider how the deep abdominal muscles responded to alterations in seated stability. The thickness of the right transverse abdominis (TrA) and internal oblique (IO) muscles were measured with ultrasound imaging in 30 healthy human subjects (mean age 27.7, years 22 females) in supine lying, relaxed sitting on a chair with both feet on the ground, relaxed sitting on a gym ball with both feet on the ground and sitting on a gym ball lifting the left foot off the floor. Measurements were taken at the end of both inspiration and expiration. The results showed that muscle thickness expressed as a percentage of the actual muscle thickness in supine lying did not differ between relaxed sitting on a chair and sitting on a gym ball for either muscle (P=0.012-0.054) where Bonferroni corrected P-value for significance=0.002. Raising the foot off the floor produced a significant increase in thickness for TrA and IO, when compared with the other seated postures (P<0.001). It was also found that both muscles were thicker at the end of expiration (P<0.001) which has also been established by other authors. These findings suggest that both deep abdominal muscles respond in the same way to postural changes. It also demonstrates that these muscles are automatically targeted by significantly decreasing the base of support, but in normal subjects sitting on a gym ball is not sufficient to increase their activity.

Abdominal Muscles↗

Assessment of tidal volume and thoracoabdominal motion using volume and flow-oriented incentive spirometers in healthy subjects.

The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne) and flow-oriented (Triflo II and Respirex) devices. Sixteen healthy subjects, 24 +/- 4 years, 62 +/- 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45 masculine). Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 +/- 268 vs 947 +/- 268 ml, P = 0.02) and minute ventilation (9.07 +/- 3.61 vs 7.49 +/- 2.58 l/min, P = 0.01) were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 +/- 1.24 vs 8.57 +/- 1.89 bpm). Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 +/- 0.05 vs 0.32 +/- 0.05 ml/s, P = 0.00, and 531 +/- 137 vs 606 +/- 167 ml/s, P = 0.00, respectively). Abdominal motion was larger (P < 0.05) during the use of volume-oriented devices compared to flow-oriented devices (52 +/- 11% for Coach and 50 +/- 9% for Voldyne; 43 +/- 13% for Triflo II and 44 +/- 14% for Respirex). We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

Abdominal Muscles↗