Search PubMedSearch

PubMed · 626420

Halothane--a new perspective.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Van Dyke. 1978. Halothane--a new perspective.. https://doi.org/10.1097/00000542-197803000-00001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[The measurement of pH and gases in the blood using microanalysis: the effect of storage at 4 degrees C for an hour. A study in the rat].

The effects of one hour storage at 4 degrees C on micro blood gas samples (150 microliters) were studied for a wide range of values (pH: 7.11-7.58; PCO2: 26-97 mmHg; PO2: 31-503 mmHg) in 20 rats with indwelling carotid artery catheters. Blood gas values were modified by varying the composition of inspired gases: normoxia, hypocapnic hypoxia, hyperoxia, hypercapnia (in this case eight animals were anaesthetized with halothane 1.1%). One hundred and eight double micro-samples were taken. For each double sample, one was analysed immediately (H0) and compared with the second sample after one hr storage at 4 degrees C (H1). The Bland and Altman method was used for the statistical analysis of results. After one hr storage at 4 degrees C, the PCO2 was slightly higher than at H0 (mean difference +/- SD: +1.08 +/- 1.7 mmHg) and arterial pH was slightly lower (mean difference +/- SD: -0.016 upH +/- 0.011 upH). These results show that for these two variables, in the range studied, one hour storage at 4 degrees C had little effect. In contrast, for arterial PO2 the mean difference between all measurements between H1 and H0 was -17 +/- 25 mmHg. If results lower than 200 mmHg (56 double samples) are considered separately, the mean difference between values at H1 and H0 was only -0.98 +/- 5.3 mmHg. For PaO2 greater than 200 mmHg (52 double samples), the mean difference was -34 +/- 26.3 mmHg; this may be due to low reproducibility of measurements of elevated PO2 levels and to the effects of cellular metabolism.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, Inhalation

The output of four modern vaporizers in the presence of helium.

It has been previously demonstrated that the output of calibrated vaporizers is influenced by the concentration of nitrous oxide in the carrier gas. This study was performed to determine whether helium in the carrier gas affects the output of modern calibrated vaporizers. A factorial design was used to determine the influence of carrier-gas helium concentration, carrier-gas flow rate and vaporizer dial setting on the output of four vaporizers: Ohio Calibrated Enflurane, Ohio Calibrated Isoflurane, Ohmeda Isotec 4, and Dräger Vapor 19.1 Isoflurane. Three vaporizers of each model were tested. Output was converted to % of baseline so that different dial settings could be compared. For a given dial setting, baseline was defined as the output at a carrier-gas flow rate of 3 L.min-1 and helium concentration of zero. The data were analyzed using multiple linear regression. There was an effect of helium concentration on vaporizer output in all models. None of these changes was clinically important, since vaporizer output did not vary by more than +/- 10%, except at high flows and at high helium concentrations with the Ohmeda Isotec 4. It is concluded that these vaporizers can be used safely with helium.

Anesthesia, Inhalation

AMPA receptor competitive antagonism reduces halothane MAC in rats.

Various subtypes of receptors have been identified for glutamate, an excitatory neurotransmitter. Previous studies have shown that antagonism of glutamate at the NMDA receptors reduces minimum alveolar concentration (MAC) for volatile anesthetics. NBQX (2,3-dihydroxy-6-nitro-7-sulfamoyl-benzo(f)quinoxaline) is a selective antagonist at the glutamatergic AMPA receptor. The purpose of this experiment was to determine whether AMPA receptor antagonism influences halothane MAC in the rat. Sprague-Dawley rats were anesthetized with halothane in 50% O2/balance N2, tracheally intubated and the lungs were mechanically ventilated. Increasing doses of NBQX were intravenously infused in three groups while the control group was infused with vehicle (D5W). Halothane MAC was then determined by the tail-clamp method. Halothane MAC was log-linearly related to plasma NBQX concentrations (MAC = 0.125 (In plasma concentration NBQX) + 1.035, r2 = 0.77). A maximal 58% reduction of halothane MAC was achieved with an NBQX loading dose of 42 mg/kg followed by a continuous infusion rate of 36 mg x kg-1 x h-1 (control = 1.02 +/- 0.07%; NBQX = 0.43 +/- 0.12%; P < .01). Larger doses of NBQX were not possible because of the poor aqueous solubility of this compound. In a separate experiment, awake rats were randomly assigned to groups based on the dose of NBQX infused. Pa(CO2) and mean arterial pressure were measured at time 0 and at 5 and 30 min after start of NBQX infusion. The infusion was then stopped. Time until recovery of the righting reflex was recorded.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, Inhalation