Search PubMedSearch

PubMed · 6242518

Realtime bloodflow imaging system utilizing auto-correlation techniques.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Namekawa, C Kasai, M Tsukamoto, A Koyano. 1983. Realtime bloodflow imaging system utilizing auto-correlation techniques.. https://pubmed.ncbi.nlm.nih.gov/6242518/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Potentials and limitations of the Valsalva maneuver as a method of differentiating between normal and pseudonormal left ventricular filling patterns.

Pseudonormalization of the left ventricular (LV) filling pattern complicates the Doppler echocardiographic assessment of LV diastolic function in patients with heart failure. The Valsalva maneuver is recommended as a method of differentiating between normal and pseudonormal LV filling patterns. However, neither a standardized Valsalva maneuver nor a healthy control population has been studied so far. Therefore, we studied changes in mitral flow velocities in response to a standardized Valsolva maneuver in 55 heart failure patients with LV systolic dysfunction and 35 control subjects. The study subjects were instructed to elevate their intrathoracic airway pressure to 40 mm Hg for 10 seconds. Doppler mitral flow velocities were recorded at rest and during the Valsalva maneuver. All study subjects had comparable decreases in early mitral flow velocity, but mitral flow velocity at atrial contraction increased rather than decreased in patients with a restrictive LV filling pattern. This markedly abnormal response might be useful in detecting elevated filling pressures and pseudonormal filling patterns. Furthermore, in all but 2 patients and all control subjects with an E/A ratio between 1 and 2, inversion of the E/A ratio occurred. This proves that, in contrast to previous beliefs, inversion of the E/A ratio does not differentiate between normal and pseudonormal LV filling patterns.

Blood Flow Velocity

P-selectin binding promotes the adhesion of monocytes to VCAM-1 under flow conditions.

This study examined the adhesive interaction of peripheral blood monocytes with VCAM-1 and analyzed the effect of P-selectin binding to monocytes on the adhesive interaction with VCAM-1 under flow conditions. P-selectin glycoprotein ligand-1 is expressed on most monocytes. Furthermore, most monocytes bind soluble P-selectin derived from platelets. P-selectin binding to monocytes did not alter the amount of expression of alpha4 integrin on monocytes. However, the mean channel fluorescence value for binding Cy2-conjugated soluble VCAM-1 to P-selectin-bound monocytes was slightly more than that for binding Cy2-conjugated soluble VCAM-1 to untreated monocytes. Under flow conditions, the number of P-selectin-bound monocytes bound to VCAM-1 was much higher than that of untreated monocytes bound to VCAM-1. These bindings were abolished by pretreatment of untreated monocytes and P-selectin-bound monocytes with anti-VCAM-1 mAb or anti-alpha4 integrin mAb. Furthermore, P-selectin binding to monocytes increased shear resistance and thus increased the adhesive strength of monocytes to VCAM-1. These findings indicate that P-selectin binding to monocytes enhances the adhesive interaction of monocytes with VCAM-1. It is suggested that P-selectin glycoprotein ligand-1/P-selectin interaction and alpha4 integrin/VCAM-1 interaction can act sequentially in the adhesion cascade that regulates monocyte trafficking to inflammatory and atherosclerotic lesion.

Blood Flow Velocity

Orientation and deformation of erythrocytes in flowing blood.

The effects of flow on the changes of electrical resistivity and light-scattering characteristics of blood are experimentally and theoretically discussed. Studies indicate that most erythrocytes deform and orient themselves in the flow direction when blood flows in a conduit. Such oriented blood shows anisotropic properties. Anisotropic electrical resistivity of flowing blood is measured in three rectangular directions with a measurement cell of coaxial cylindrical type. From these experimental results, the orientation and deformation of erythrocytes are discussed. The orientation ratio and the deformation are calculated using a simplified spheroidal model of an erythrocyte. Calculated results show that the fractions of erythrocytes with their short axis parallel to each direction and the equivalent axis ratio for a simplified spheroidal model change with the shear rate of flow.

Blood Flow Velocity