Interference in pacemakers.

Abstract

We attempt here to outline the different sources of interference and the methods of interference detection and protection with their advantages and disadvantages. A proposal is made as to how a better interference suppression could be established. A comparison of 16 pacemakers from ten manufacturers tested with different interference sources revealed a great variety, which does not allow one to generalize the problem of interference. As an example, an electric steel furnace with its magnetic field is described and how its influence on pacemakers can be estimated. Rules are given as to how pacemaker patients may be treated by electrotherapy. A test procedure for characterizing the specific interference behavior is proposed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Irnich. 1984. Interference in pacemakers.. https://doi.org/10.1111/j.1540-8159.1984.tb05655.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Resolution of high molecular weight proteins in dependence on electric field strength in polyacrylamide gel electrophoresis.

Resolution of high molecular weight proteins, in the upper region of polyacrylamide gels, was studied in relation to the type of electric field. Separations by constant field gel electrophoresis (CFGE) were compared to those in pulsed oscillatory high-performance electrophoresis (POPE), a novel technique which allows electrophoresis at high field strengths owing to a novel local field distribution. This distribution contributes to structural and mechanical stability of the gel with resultant well-reproducible separation, enhanced resolution, and higher absolute mobility of proteins in POPE.

Electricity

Experimental correlation-based identification of X-ray CT point spread function. Part 1: Method and experimental results.

Knowledge of the point spread function (PSF) of an imaging system is important when studying the characteristics of the blur present in the images. Published experimental PSF identification techniques adapt classical one-dimensional linear system identification strategies using impulse, step function or periodic input signals. This study proposes and successfully applies a correlation method based on the Wiener-Hopf equation to identify the PSF of a CT scanner. The input consists of a series of pseudorandomly located holes. Results are found to be statistically equivalent to those obtained with the impulse method at a 90% two-sided confidence interval. Like the impulse method, it readily yields two-dimensional estimate, but the larger input circumvents the major objection to the use of a wire input. Furthermore, it is relatively immune to output noise, offering an advantage over edge methods. This resistance to noise may prove helpful for nuclear medicine imaging techniques, for which the signal-to-noise ratio is much lower than that X-ray for CT.

Electricity