Search PubMed⌕ Search

PubMed · 6154784

Immune complexes in multiple sclerosis: relation to clinical pattern.

Abstract

Using a C1q binding test, circulating immune complexes (IC) were detected in 33.3% of sera from 138 patients and in 19.4% of 124 spinal fluid samples from patients with multiple sclerosis. Most often they occur in sera alone. As a rule their detectable amount is small in sera as well as in spinal fluids. IC were observed with equal frequency during acute exacerbations and in stable phases of the disease. In patients with early MS of less than 3 months duration, IC were detected only rarely, whereas their frequency increased up to 50% in patients with longer standing disease. Immunosuppressive therapy has no influence on IC formation. Patients with immune complexes exhibited a more rapid clinical deterioration if compared as a group with IC-negativ ones. No correlations were found between immune complex formation and the CSF-IgG index or the rate of pleocytosis in spinal fluids. Neither the complement factors C3, C4, C3A nor total hemolytic complement activities (CH50) in serum were significantly decreased in patients with IC formation in serum as compared with the IC-negative group. The results demonstrate that IC formation probably is of no importance in the pathogenesis of multiple sclerosis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Patzold, P Haller, B Baruth, W Liman, H Deicher. 1980. Immune complexes in multiple sclerosis: relation to clinical pattern.. https://doi.org/10.1007/bf00313154

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗