Measuring partial thromboplastin-time. An international collaborative study.

Abstract

A series of collaborative exercises on the partial thromboplastin-time (P.T.T.) test, involving over three hundred hospital centres in Britain and overseas, were performed in 1975. Lyophilised test plasmas were issued from the World Health Organisation Collaborating Centre for Anticoagulant Control Reagents to participants, together with a standardised reference P.T.T. reagent and a standard technique. Hospitals were asked to test the plasma samples with the standardised reagent and technique in parallel with their customary local P.T.T. reagent and method. The overall success-rate in detecting the intrinsic clotting abnormality in the eight abnormal test samples was higher with the standardised reagent and technique than with all other reagents. Furthermore, fewer hospitals obtained false positive results when the normal plasma sample was tested with the standardised method rather than with their usual routine reagents. An index was used to measure the success-rate of the P.T.T. reagents in correctly identifying the test plasmas as normal or abnormal. The eight test plasmas showed a varying degree of abnormality. A system of "weighting" was therefore introduced as the failure of a P.T.T. method to detect more severe defects was regarded as more serious. Although hospitals were unfamiliar with the standardised method, the results established its superiority over all other P.T.T. reagents included in the trials in sufficient numbers for analysis. Failures with commercial reagents may have been caused by insensitivity of the cephalin extracts or the unreliability of the manufacturers recommended techniques. Since the same laboratories obtained good results with the standardised method technical failure can be excluded.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Poller, J M Thomson. 1976-10-16. Measuring partial thromboplastin-time. An international collaborative study.. https://doi.org/10.1016/s0140-6736(76)91224-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecular characterization of an Italian patient with plasminogen deficiency and ligneous conjunctivitis.

Plasminogen deficiency is a rare disease characterized by ligneous conjunctivitis and infections. We observed a 3-year-old Italian boy presenting ligneous conjunctivitis and low plasma levels of plasminogen. Twenty-three different mutations on the PLG gene have been reported to date, but mutation analysis had been troublesome for the presence of highly homologous genes. The aim of the study was to identify the underlying mutation avoiding coamplification of unwanted genetic materials using a long polymerase chain reaction strategy, instead of the previously reported subcloning methods. By this simple strategy the complete sequence analysis of PLG gene was performed, and a previously reported missense homozygous mutation (K19E) was identified.

Blood Coagulation Disorders↗

Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

BACKGROUND: Reagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma. OBJECTIVES: The goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion. METHODS: Ninety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM). RESULTS: Trauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively. CONCLUSIONS: ROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

Blood Coagulation Disorders↗