Search PubMed⌕ Search

PubMed · 6020036

Pattern classification by adaptive machines.

Abstract

Man's intelligent behavior is due in part to his ability to select, classify, and abstract significant information reaching him from his environment by way of his senses. This function, pattern recognition, has become a major focus of research by scientists working in the field of artificial intelligence. At the lowest level, pattern recognition reduces to pattern classification, which consists of the separation, into desired classes, of groups of objects, sounds, odors, events, properties, and the like; the separations are based on sets of measurements made on the entities being classified. The pattern classifier is composed of a data filter and a categorizer. The data filter selects the distinguishing features and represents them as sets of real numbers; each set is termed a pattern. The categorizer assigns each pattern to one of several desired classes. Patterns can be represented geometrically as points in an n-dimensional space; the n coordinates of each point are the numerical values of the features selected to represent the pattern. A pattern classification system separates an n-dimensional space into regions, each of which ideally contains points of only one class. One method to effect this separation is by means of ldquo;trainablerdquo; categorizers-major components of adaptive machines. They consist of networks whose internal parameters are varied according to a set of fixed rules during a training cycle. A statistically large sample of known patterns are presented, one at a time, to the networks; internal corrections are made each time a pattern is erroneously classified. Classifica-tion performance tends to improve as the set of known patterns is cycled repetitively through the machine. Finally, the adequacy of adaptation is tested by a separate set of similar patterns which have not been used in the training process. A number of different machine organizations and training rules have been developed and are being applied successfully to numerous classification problems. More difficult recognition problems requiring the aid of logioal tests and analysis, search and association, use the digital computer programmed to supplement the functions of the adaptive classifier.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C A Rosen. 1967-04-07. Pattern classification by adaptive machines.. https://doi.org/10.1126/science.156.3771.38

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology.

Patient and staff dose values in an interventional cardiology laboratory for different operational modes and several patient thicknesses (from 16 to 28 cm, simulated using polymethylmethacrylate) are presented. When increasing patient thicknesses and depending on fluoroscopy and cine modes, occupational doses can increase >30 times the baseline level. Scatter dose rates at the cardiologist's position with no radiation protective tools ranged from 1 to 14 mSv h(-1) for fluoroscopy, and from 10 to 47 mSv h(-1) during cine acquisition. Patient entrance surface air kerma rates increased by nearly 3 and staff dose rates by up to 2.6 when fluoroscopy was moved from the low to the high mode, for a typical 20 cm thickness. The respective increase factors were 6 and 4.2 when patient thickness rose from 16 to 28 cm, and by 10 and 8.3, when comparing cine acquisition with the low fluoroscopy mode. The knowledge of typical dose rates for each X-ray system in use in catheterisation laboratories is essential in order to optimise protection of patients and staff.

Body Constitution↗

Simulator-assisted setting of scan protocols for X-ray CT: development and clinical usefulness of the Scan Plan Simulator.

To assist in the selection of complicated computed tomography (CT) scan protocols and to obtain stable image SD values, prototype "Scan Plan Simulator" software with the following functions was developed and evaluated. 1) The image SD value that will be obtained in actual scanning is estimated by entering the patient's body size and scan protocol, after which a simulated image is displayed so that the estimated image SD value can be checked. The exposure dose can also be estimated in the Scan Plan Simulator. 2) The appropriate tube current is automatically set by entering the required image SD value. We evaluated the accuracy of the Scan Plan Simulator by comparing the simulation results with the image SD values and exposure dose obtained in actual scanning and assessed the usefulness of this method using Monte Carlo simulation based on body thickness data obtained in clinical examinations. The results showed that the Scan Plan Simulator not only stabilizes image SD by minimizing the effects of body size but also permits the exposure dose to be reduced by optimizing tube current.

Body Constitution↗