Search PubMedSearch

PubMed · 6003928

A versatile galvanometer-driver amplifier.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A A Meijer. 1966. A versatile galvanometer-driver amplifier.. https://doi.org/10.1007/bf02474792

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Improved micro-perfusion chamber for multiple and rapid solution exchange in adherent single cells.

A new method for fast perfusion of single adherent cells during whole-cell and single-channel patch-clamp measurements is described. The main advantages over previous methods are: (1) the solution surrounding a single cell in a Petri dish (or cover slip) can be exchanged without contamination of the entire cell population, and (2) only small quantities of test solution (50 microliters) are required. The method consists of inserting a patch pipette into a micro-perfusion chamber (MPC) where whole-cell and single-channel currents can be studied. A small volume (2-3 microliters) surrounding adherent single cells in a Petri dish is separated by enclosing it in a ring of Silicone rubber which is then pressed to the bottom of the dish. A drug-containing test solution (50 microliters) is supplied to a funnel at the chamber inflow. The MPC volume isolated from the main solution in the Petri dish is rapidly changed when suction is applied to the chamber outflow. The speed of solution exchange in the MPC (16 +/- 5 ms, n = 12) was estimated by observing changes in the tip potential of 1-M omega patch pipettes during rapid chamber perfusion with solutions of different ionic composition. The seal of the MPC with the surface of a Petri dish was approximated by measuring the electrical resistance between the MPC interior and a reference electrode placed in the Petri dish outside the MPC (range 300-500 M omega). Additionally, a radioactive calcium channel ligand [3H]isradipine was added to the MPC and the appearance of radioactivity in the Petri dish (outside the MPC) subsequently measured.(ABSTRACT TRUNCATED AT 250 WORDS)

Amplifiers, Electronic

Design and evaluation of shielded gradient coils.

Techniques are described for the design of shielded gradient coils for superconducting MRI systems. These design methods are suited for constructing the most efficient gradient coil that meets a specified homogeneity requirement. Tradeoffs in coil design of efficiency with coil size and gap size are discussed. Residual eddy currents from coils constructed with a finite number of wires are calculated and give guidelines for the construction of efficient, whole-body gradient coils.

Amplifiers, Electronic