Search PubMedSearch

PubMed · 5960497

[Emergency tests--Hemoglobin].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Nomura. 1966. [Emergency tests--Hemoglobin].. https://pubmed.ncbi.nlm.nih.gov/5960497/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[A simple, lightweight device for measurement of hemoglobin; the HemoCue Blood Hemoglobin Test].

In some situations such as a sudden bleeding during surgery, rapid testing of blood hemoglobin concentration is necessary. The HemoCue Blood Hemoglobin Test uses a lightweight photometer, which is easily movable anywhere. The HemoCue needs only 10 microliters of blood and it takes only about 45 seconds to produce the result. Therefore, the device might be useful in the operating suite and the emergency unit. To evaluate the accuracy of the HemoCue, we compared the blood hemoglobin concentrations measured by the HemoCue with those measured by the ABL 300. A positive correlation was found between the variables by the HemoCue (Y) and those by the ABL 300 (X); Y = 0.944X - 0.208, r = 0.97, P < 0.001. It is concluded that the HemoCue is a reliable device for measurement of blood hemoglobin concentration.

Hemoglobinometry

[How to achieve analytical reliability of hemoglobinometry].

Three kits of reagents manufactured by RENAM Research and Production Unit provide the analytical reliability of hemoglobinometry. The kits contain: 1) dry powder transforming agent; 2) four calibration standard solutions of hemoglobin cyanate requiring no dilution; 3) three highly purified stable solutions of hemoglobin (simulating human blood) with attested concentrations of hemoglobin from 50 to 200 g/liter.

Hemoglobinometry

The Erlanger Microlightguide Photometer: a new concept for monitoring intracapillary oxygen supply of tissue--first results and a review of the physiological basis.

The local oxygen supply to the skin immediately before and after withdrawal of blood was appraised in 18 healthy test subjects by measuring the intracapillary hemoglobin oxygenation (HbO2). The investigation was carried out with the Erlanger Microlightguide Photometer (EMPHO). EMPHO measurements are based on the registration of tissue remission spectra from which the HbO2 values are calculated using the Kubelka-Munk theory. The results show that global parameters do not reflect the supply of oxygen to the tissue; for example, in hypovolemia, the physiological response to the pathophysiological stimulus is centralization. This is manifested at a very early stage in the skin, before the oxygen supply to other organs (e.g., liver, kidney, gut) is affected. The disturbance of the local cutaneous oxygen supply is reflected in a change in the intracapillary hemoglobin oxygenation of the skin. Hence, one might consider measurements of the local oxygen supply to the skin as an early indicator for centralization.

Hemoglobinometry