Search PubMed⌕ Search

PubMed · 5784293

Impulse functions for human rod vision.

Abstract

1. This paper presents accurate increment threshold data for human rod vision for a small number of experimental parameters. The test is small and brief and the large background is either steady or transient.2. The linear threshold disturbance due to an impulse background consists of an input dependent exponential growth phase and an exponential recovery phase of more or less fixed time constant (ca. 0.08 sec).3. The data are treated by applying signal/noise decision theory to a hypothetical filter with two shot noise inputs, viz. the testing signal and the background. The gain and time course of the impulse function of the filter are slightly affected by the magnitude of the input.4. A linear approach is useful since the impulse functions for dark or light-adapted rod vision yield independent information about quantities which have previously only been used to describe the increment thresholds for small tests on steady backgrounds, viz. the integration time and dark light of the fully dark-adapted eye and the gain changes (or changes in the signal/background ratio) which occur on progressive light adaptation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P E Hallett. 1969. Impulse functions for human rod vision.. https://doi.org/10.1113/jphysiol.1969.sp008817

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗