Search PubMed⌕ Search

PubMed · 5698747

Engineers design limbs.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1968-11-23. Engineers design limbs.. https://pubmed.ncbi.nlm.nih.gov/5698747/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact.

When compared with automated contact methods of finite element (FE) analyses, gap elements have certain inherent disadvantages in simulating large slip of compliant materials on stiff surfaces. However, automated contact has found limited use in the biomechanical literature. A non-linear, three-dimensional, geometrically accurate, FE analysis of the trans-tibial limb-socket prosthetic system was used to compare an automated contact interface model with a gap element model, and to evaluate the sensitivity of automated contact to interfacial coefficient of friction (COF). Peak normal stresses and resultant shear stresses were higher in the gap element model than in the automated contact model, while the maximum axial slip was less. Under proximally directed load, compared with automated contact, gap elements predicted larger areas of stress concentration that were located more distally. Gap elements did not predict any relative slip at the distal end, and also transmitted a larger proportion of axial load as shear stress. Both models demonstrated non -linear sensitivity to COF, with larger variation at lower magnitudes of COF. By imposing physical connections between interface surfaces, gap elements distort the interface stress distributions under large slip. Automated contact methods offer an attractive alternative in applications such as prosthetic FE modeling, where the initial position of the limb in the socket is not known, where local geometric features have high design significance, and where large slip occurs under load.

Artificial Limbs↗

Use of Van Nes rotationplasty to manage a burnt knee.

An 11 month old child sustained a deep burn injury to the left knee causing total destruction and sequestration of the knee epiphyses. The ensuing leg length discrepancy with growth was managed by a Van Nes rotationplasty at age four with a good immediate functional result using a below 'knee' prosthesis and the prospect of continuing ambulation as he grows. The surgical options for managing this problem are discussed.

Artificial Limbs↗