Search PubMedSearch

PubMed · 566510

New developments in photocoagulation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Ducrey. 1978. New developments in photocoagulation.. https://pubmed.ncbi.nlm.nih.gov/566510/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dynamic optical property changes: implications for reflectance feedback control of photocoagulation.

During laser treatment, coagulation affects the optical properties of the tissue. In particular, the formation of a white lesion significantly increases the scattering coefficient. This change in the optical properties in turn affects the laser light distribution in the tissue. The white lesion formed during photocoagulation of the retina has a dynamic effect upon reflection and fluence rate. This problem has been simulated on a model medium consisting of a thin absorbing layer covered with a 1 cm thick layer of albumin. The albumin layer is subdivided into coagulated (white) and uncoagulated (clear) layers. The optical properties of each layer have been determined and these values have been used to model light distribution in the medium. One-dimensional adding-doubling and three-dimensional Monte Carlo methods have provided light distributions in the medium for varying thicknesses of the coagulated albumin. Computed fluence reaching the absorbing layer decreased in the presence of a 275 microns or thicker coagulated layer. The coagulated layer attenuates light because it is highly scattering; however, this scattering also leads to a sub-surface peak in fluence rate at a level higher than the incident fluence. The latter effect outweighed the former for coagulated layer thicknesses less than 275 microns. Computed reflectance of argon laser light from a semi-infinite coagulated region initially increased linearly as a function of thickness. As the coagulation thickness increased beyond 4-5 optical depths, the reflectance approached a constant value, R infinity, at 9 optical depths (2 mm). Experimentally measured total reflectance is shown to be an inadequate indicator of the thickness of a lesion (finite coagulated volume); however, central reflectance from a lesion measured with a CCD camera confirmed the computed trends. These results provide a theoretical foundation for control of lesion thickness using reflectance images.

Argon

Degradation, amorphization, and recrystallization of ion bombarded Si(111) surfaces studied by in situ reflection electron microscopy and reflection high energy electron diffraction techniques.

In this paper we report the effect of noble gas ions bombardment on the degradation of atomically flat Si(111) surfaces at room and high (400 degrees C-600 degrees C) temperatures. Reflection high energy electron diffraction (RHEED) and reflection electron microscopy (REM) have been used to characterize the topography and structure of the as-implanted and post annealed surface layers. It is shown that the fading of the specularly reflected beam is not directly related to the amorphization of the surface. This experimental study has also evidenced the difficulties one meets to regrow a defect-free material after amorphization by noble gas bombardment. For high temperature for which the amorphization is not possible, the surface loses its stepped structure and turns into a monocrystalline but atomically rough surface. This roughness is a function of substrate temperature.

Argon