Search PubMedSearch

PubMed · 5483453

Mammography.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N L Mills. 1970. Mammography.. https://pubmed.ncbi.nlm.nih.gov/5483453/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Patterns of mammographically detected calcifications after breast-conserving therapy associated with tumor recurrence.

BACKGROUND: Some authors have suggested that mammographically evident calcifications that would be considered benign in other situations can be due to carcinoma in women who have undergone breast conservation. This study was undertaken to determine if the pattern of calcifications associated with recurrent tumors detected mammographically differs from that observed in carcinomas developing de novo. METHODS: Mammograms of 22 cases of local tumor recurrence were retrospectively reviewed, and calcifications associated with recurrence were characterized according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) classification. RESULTS: Tumors were usually associated with > or = 10 calcifications (77%; 17 of 22 cases). Recurrences commonly contained very suspicious patterns of calcifications with linear forms present in 15 cases (68%) and pleomorphic calcifications present in 17 cases (77%). The distribution of calcifications was usually clustered (73%; 16 of 22 cases) or segmental (18%; 4 of 22 cases). Recurrences were usually obviously malignant (BI-RADS Category 5), and were characterized as such in 77% of cases. The remainder were indeterminate, requiring biopsy (BI-RADS Category 4). Recurrent tumors containing calcifications always contained some suspicious forms. Less worrisome types of calcifications were sometimes observed, including punctate calcifications in 36% and coarse calcifications in 14% of cases, but were always associated with more malignant patterns. CONCLUSIONS: Local tumor recurrences, when associated with mammographically evident calcifications, usually have a pattern highly suspicious for malignancy, although indeterminate forms can be the only calcifications present. Characteristically benign patterns of calcifications are not observed in recurrent tumors unless they are associated with more suspicious calcifications. Therefore, women without more worrisome patterns need not undergo biopsy because of the presence of these nonworrisome calcifications.

Breast Diseases

Comparison of indium-111 octreotide and thallium-201 scintigraphy in patients mammographically suspected of having breast cancer: preliminary results.

Indium-111 octreotide and thallium-201 scintigraphic studies were compared in 21 patients (16 with palpable and five with non-palpable lesions) suspected of having breast malignancies on the basis of mammography. Early (15 min) and late (3 h) 201Tl (111 MBq) and 4-h and 24-h 111In-octreotide (111-148 MBq) static planar anterior images (matrix 256 x 256) were obtained on separate days. Images were evaluated both visually and quantitatively. Biopsy was performed following the imaging studies. Histopathology revealed 17 breast carcinomas (15 cases of invasive ductal carcinoma, one mucinous adenocarcinoma and one intraductal carcinoma) and four benign breast lesions (two fibroadenomas, one abscess and one case of fat necrosis). The means histopathological tumour size (mean largest diameter) was 3.38 +/- 1.9 cm. 111In-octreotide detected 16 of the 17 breast cancers (94%) while 201Tl detected 13 of them (76%). Both 111In-octreotide and 201Tl missed one non-palpable carcinoma showing only an isolated cluster of microcalcifications on mammography. The smallest tumour size detected by both agents 1.5 x 1.5 cm. Of the four benign lesions, only the breast abscess revealed both 201Tl and 111In-octreotide uptake. 111In-octreotide scan also showed tracer uptake in five of the six patients with histologically proven axillary metastases, while four of these six patients showed 201Tl uptake. The tumour/background (T/B) ratios of late 111In-octreotide and 201Tl images were 1.71 +/- 0.38 and 1.46 +/- 0.30 respectively (P = 0.039). In this preliminary study, 111In-octreotide yielded more favourable results than 201Tl in the detection of breast carcinomas. However, the diagnostic efficacy of 111In-octreotide imaging needs to be investigated in larger patient series.

Breast Diseases