Search PubMedSearch

PubMed · 5449652

[Blood sequestration].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Larcan, M Calamai, A M Voiry-Camez. 1970. [Blood sequestration].. https://pubmed.ncbi.nlm.nih.gov/5449652/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plasma volume and its regulatory factors in congestive heart failure after implantation of long-term left ventricular assist devices.

BACKGROUND: Congestive heart failure is associated with blood volume expansion caused by stimulation of the renin-aldosterone system and arginine vasopressin. The use of left ventricular assist devices as bridges to heart transplantation has improved the survival of patients during this critical period. In studying heart failure physiology on support devices, we hypothesized that improvement of cardiac function by a left ventricular assist device is associated with normalization of volume load secondary to normalization of its regulatory substances. METHODS AND RESULTS: We studied 15 patients (13 men, 2 women: age 51 +/- 8 years) with end-stage heart failure who were cardiac transplant candidates eligible for HeartMate implantation. We measured plasma volume and plasma levels of atrial natriuretic peptide, aldosterone, renin, and arginine vasopressin sequentially before HeartMate implantation (baseline), after HeartMate implantation (weeks 4 and 8), and after transplantation. Baseline plasma volume was 123 +/- 20% of normal; it was 122 +/- 22% at week 4 and decreased to 115 +/- 14% at week 8. Atrial natriuretic peptide was 359 +/- 380 pg/mL at baseline, 245 +/- 175 pg/mL at week 4, and 151 +/- 66 pg/mL at week 8. Plasma aldosterone fell from 68 +/- 59 ng/dL at baseline to 17 +/- 16 ng/dL at week 4 (P < .05 versus baseline) and was 32 +/- 50 ng/dL at week 8. Plasma renin activity decreased from 80 +/- 88 ng/dL at baseline to 11 +/- 12 ng/dL at week 4 and was 16 +/- 38 ng/dL at week 8 (both P < .05 versus baseline). Arginine vasopressin fell from 5.0 +/- 4.8 fmol/mL at baseline to 1.1 +/- 0.7 fmol/mL at week 4 and 1.2+/-0.8 fmol/mL at week 8 (both P < .05 versus baseline). CONCLUSIONS: The reduction of plasma renin activity, plasma aldosterone, and arginine vasopressin occurred earlier than the reduction of plasma volume and atrial natriuretic peptide after HeartMate implantation, possibly because of decreased pulmonary congestion and improved renal perfusion. The reduction of atrial natriuretic peptide cannot be responsible for the lack of adequate decrease of plasma volume; its reduction can be taken as a marker of improved cardiac pump function and decreased atrial stretch.

Blood Volume

Application of a superparamagnetic iron oxide (Resovist) for MR imaging of human cerebral blood volume.

The authors describe the feasibility of dynamic MRI using a novel superparamagnetic iron oxide contrast agent. Resovist was injected as a bolus at doses of 4, 8, and 16 mumol Fe/kg bodyweight in three consented patients participating in a Phase 2 clinical multicenter trial for hepatic MRI. Dynamic images of the brain were obtained with a conventional FLASH sequence. Results were analyzed by evaluation of dynamic images, cerebral blood volume maps, and normalized signal intensity time curves. Resovist enabled rapid injections and a dose-dependent strong reduction in gray and white matter signal intensity. The small injection volume and good tolerability may enable Resovist to serve as a perfusion agent. Dedicated clinical trials are warranted to assess the potentials of Resovist for perfusion MRI and fMRI.

Blood Volume

Comparison of different oxygen exchange models.

A functional distribution of coronary volume can be estimated from the response of arterio-venous O2 content difference (AVO2) to a flow step. However, the results depend on the assumed O2 exchange model. The previously used model consisted of a single mixed compartment with O2 exchange (reference model). The purpose of this study is to provide an estimate of the errors made in the volume estimations by not taking into account factors as flow heterogeneity, different mixing sites or Krogh-like O2 exchange. The approach is indirect: the response of the AVO2 to a flow step has been calculated with alternative O2 exchange models in which factors mentioned are incorporated. These transients are fitted with the reference model. The resulting estimated volumes are different from the volumes assumed in the alternative models. Large differences are obtained with some of the alternative models, e.g. the model with Krogh characteristics. However, these models seem unrealistic because capillary pO2 is higher than venous pO2. Only small differences in volume are obtained with the more realistic models. Therefore, these results indicate that the coronary volumes are approximated well by the estimations obtained with the reference model. These volume estimations were 9.9 and 3.8 ml 100 g-1 for the O2 exchange vessels and the distal venous volume, respectively.

Blood Volume