Search PubMed⌕ Search

PubMed · 537345

A dynamometer for biomechanical use.

Abstract

A dynamometer has been designed for measuring isometric forces in human body limb segments. The dynamometer constrains the chosen segment, and measures two orthogonal components of the force reaction between the segment and the dynamometer in a plane perpendicular to the long axis of the segment, plus the torque reaction parallel to the long axis of the segment. The testing and operating characteristics of the dynamometer are described, and it is concluded that in view of its versatility and accuracy, the dynamometer may be suitable both for research and for clinical use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R H Nathan. 1979. A dynamometer for biomechanical use.. https://doi.org/10.1016/0141-5425(79)90062-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biomechanical assessment of lateral stiffness elements in the suspension system of a backpack.

The purpose of this study was to examine the change in load distribution characteristics associated with adding lateral stiffness elements (rods) to a rucksack (backpack). A load distribution mannequin was instrumented with two 3D load cells to allow determination of the load applied to the shoulders and upper torso independent of the load applied to the hips and lower trunk. Position and mass of the payload (25 kg) were fixed at the centre of the volume of the rucksack and held constant during all testing. It was hypothesized that lateral rods would provide a force bridge that transfers part of the vertical load of the pack from the upper back and shoulders to the hip belt thereby reducing the vertical load on the torso, and possibly reducing the horizontal reaction force that produces a shear load on the spine. Results showed that these active stiffness elements shifted 14% of the vertical load from the upper torso to the pelvic region with lumbar shear load remaining relatively unchanged for all combinations of shoulder strap and waist belt tension. The lateral rods also provided a mean increase of 12% in the extensor moment at the L3-L4 level, thus reducing some demand on the erector spinae muscles.

Biomechanical Phenomena↗

A suite of objective biomechanical measurement tools for personal load carriage system assessment.

For application to military and civilian needs, Defence Research and Development Canada--Toronto contracted Queen's University, Kingston to develop a suite of biomechanical assessment and analytical tools to supplement human-based load carriage system assessment methods. This suite of tools permitted efficient objective evaluation of biomechanical aspects of load-bearing webbing, vests, packs and their components, and therefore contributed to early system assessment and a rapid iterative design process. This paper is a summary of five assessment and analytical tools. A dynamic load carriage simulator was developed to simulate cadence of walking, jogging and running. The simulator comprised a computer-controlled pneumatic platform that oscillated anthropometrically weighted mannequins of varying dimensions from which measures of skin contact pressure, hip reaction forces and moments and relative pack-person displacements were taken. A stiffness tester for range of motion provided force-displacement data on pack suspension systems. A biomechanical model was used to determine forces and moments on the shoulders and hips, and validated using a static load distribution mannequin. Subjective perceptual rating systems were used gather soldier feedback during a standardized mobility circuit. Objective outcome measures were validated by means of other objective measures (e.g., Optotrak, video, Instron, etc.) and then compared to subjective ratings. This approach led to development of objective performance criteria for load carriage systems and to improvements in load carriage designs that could be used both in the military and in general.

Biomechanical Phenomena↗

A model of cerebellum stabilized and scheduled hybrid long-loop control of upright balance.

A recurrent integrator proportional integral derivative (PID) model that has been used to account for cerebrocerebellar stabilization and scaling of transcortical proprioceptive feedback in the control of horizontal planar arm movements has been augmented with long-loop force feedback and gainscheduling to describe the control of human upright balance. The cerebellar component of the controller is represented by two sets of gains that each provide linear scaling of same-joint and interjoint long-loop stretch responses between ankle, knee, and hip. The cerebral component of the model includes a single set of same-joint linear force feedback gains. Responses to platform translations of a three-segment body model operating under this hybrid proprioception and force-based long-loop control were simulated. With low-velocity platform disturbances, "ankle-strategy"-type postural recovery kinematics and electromyogram (EMG) patterns were generated using the first set of cerebeller control gains. With faster disturbances, balance was maintained by including the second set of gains cerebellar control gains that yielded "mixed ankle-hip strategy"-type kinematics and EMG patterns. The addition of small amounts of simulated muscular coactivation improved the fit to certain human datasets. It is proposed that the cerebellum switches control gainsets as a function of sensed body kinematic state. Reduction of cerebellar gains with a compensatory increase in muscular stiffness yielded posture recovery with abnormal motions consistent with those found in cerebellar disease. The model demonstrates that stabilized hybrid long-loop feedback with scheduling of linear gains may afford realistic balance control in the absence of explicit internal dynamics models and suggests that the cerebellum and cerebral cortex may contribute to balance control by such a mechanism.

Biomechanical Phenomena↗