Search PubMed⌕ Search

PubMed · 5358935

Practical course in instruments and electronics. I. Electronic components.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L W Price. 1969. Practical course in instruments and electronics. I. Electronic components.. https://pubmed.ncbi.nlm.nih.gov/5358935/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design and evaluation of a novel portable erythema-melanin-meter.

BACKGROUND AND OBJECTIVES: Objective evaluation of the pigmentation index (PI) and the eythema index (EI) of human skin is a prerequisite for successful optimization of laser- and intense-pulsed-light (IPL)-based treatment modalities in dermatology. STUDY DESIGN/MATERIALS AND METHODS: We describe a three-wavelength technique for determining PI and EI as well as its particular implementation using LEDs operating at wavelengths of 560, 650, and 710 nm and a large-area photodiode. The instrument has been evaluated both in vitro and in vivo. RESULTS: In vitro, good correlation between the measured indices and results obtained with commercially available techniques has been observed. In addition, linearity of the PI with melanin concentration in the phantom medium up to 7 x 10(-3) nm(-1) (defined as a slope of the optical density spectrum) has been established. In vivo, feasibility of using the technique for predicting the minimal erythema dose (MED), minimal phototoxic dose (MPD), and the threshold of epidermal damage in a photothermal treatment has been demonstrated. CONCLUSIONS: The data suggest that the technique has a substantial potential as a method of pre-treatment diagnostics for photochemical and photothermal procedures.

Electronics, Medical↗

Effect of an imaging-based streamlined electronic healthcare process on quality and costs.

RATIONALE AND OBJECTIVES: A streamlined process of care supported by technology and imaging may be effective in managing the overall healthcare process and costs. This study examined the effect of an imaging-based electronic process of care on costs and rates of hospitalization, emergency room (ER) visits, specialist diagnostic referrals, and patient satisfaction. MATERIALS AND METHODS: A healthcare process was implemented for an employer group, highlighting improved patient access to primary care plus routine use of imaging and teleconsultation with diagnostic specialists. An electronic infrastructure supported patient access to physicians and communication among healthcare providers. The employer group, a self-insured company, manages a healthcare plan for its employees and their dependents: 4,072 employees were enrolled in the test group, and 7,639 in the control group. Outcome measures for expenses and frequency of hospitalizations, ER visits, traditional specialist referrals, primary care visits, and imaging utilization rates were measured using claims data over 1 year. Homogeneity tests of proportions were performed with a chi-square statistic, mean differences were tested by two-sample t-tests. Patient satisfaction with access to healthcare was gauged using results from an independent firm. RESULTS: Overall per member/per month costs post-implementation were lower in the enrolled population (126 dollars vs 160 dollars), even though occurrence of chronic/expensive diseases was higher in the enrolled group (18.8% vs 12.2%). Lower per member/per month costs were seen for inpatient (33.29 dollars vs 35.59 dollars); specialist referrals (21.36 dollars vs 26.84 dollars); and ER visits (3.68 dollars vs 5.22 dollars). Moreover, the utilization rate for hospital admissions, ER visits, and traditional specialist referrals were significantly lower in the enrolled group, although primary care and imaging utilization were higher. Comparison to similar employer groups showed that the company's costs were lower than national averages (119.24 dollars vs 146.32 dollars), indicating that the observed result was not attributable to normalization effects. Patient satisfaction with access to healthcare ranked in the top 21st percentile. CONCLUSION: A streamlined healthcare process supported by technology resulted in higher patient satisfaction and cost savings despite improved access to primary care and higher utilization of imaging.

Electronics, Medical↗

Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.

Electronics, Medical↗