A multisample applicator for quantitative thin-layer chromatographic analysis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J S Chahl, C C Kratzing. 1969. A multisample applicator for quantitative thin-layer chromatographic analysis.. https://doi.org/10.1016/0009-8981(69)90306-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thin-layer chromatographic procedures for lipid separation.

This review focuses on the thin-layer chromatographic (TLC) separation aspects of lipid analysis. Since the space limitations do not permit, the quantitative aspects of the analyses are not discussed at length although some indications of appropriate methodology and detection reagents will be indicated. Many separations carried out by TLC have the prerequisite of proper sample preparation. Using proper sample clean-up prior to TLC enables one to carry out precise separation as well as sensitive quantitation. Thus, the discussions are divided into the two main topics--sample preparation and TLC. Examples of applications are limited to those which illustrate the capabilities of the technique as well as practicability. Since there are a number of reviews in the literature, the discussions herein are focused mainly on reports after 1985.

Chromatography, Thin Layer

Dispersion state of phospholipids and fluorescence production with peroxidation in organic solvents: investigated by time-resolved fluorescence technique.

Fluorescent substances were found to be produced efficiently when phospholipids containing phosphatidylethanolamine (PE) and linoleic chains were autoxidized in non-polar solvents. By using these fluorescent substances as intrinsic probes, the dispersion state of phospholipids was investigated in various organic solvents. Fluorescence anisotropy decay measurements indicated that the aggregation size of phospholipids was much larger in hexane than in chloroform, methanol and tert-butyl alcohol. The average diameter of phospholipid aggregates in hexane was calculated to be 4-6 nm, which was dependent on the lipid composition. A consistent result was obtained when N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)-1,2-dihexadecanoyl-sn-gly cer o-3- phosphoethanolamine (NBD-PE) was used as an extrinsic probe. Comparison of the fluorescence data with small-angle X-ray scattering (SAXS) data suggested that a reverse micellar structure of phospholipids formed in hexane. It was shown that phospholipid aggregation enhanced the extent of peroxidation as well as the production yield of fluorescent substances of phospholipid.

Chromatography, Thin Layer

Degradation of dansyl polyamines on high-performance thin-layer chromatographic plates.

Using high-performance thin-layer chromatography with in situ quantitation to measure dansylated polyamines in the range of 1-20 pmol, we found that dansylated polyamines apparently react with the silica gel of the plates. The fluorescence of the dansyl polyamines diminished with increase in the time interval between application of a sample to the plate and start of the chromatographic separation. Conversely, the fluorescence at the site of application increased with the length of the time interval, indicating the formation of polar reaction products. If this reaction is not accounted for, considerable errors in quantitation of dansyl polyamines may occur.

Chromatography, Thin Layer