Search PubMed⌕ Search

PubMed · 5130537

Quality control in routine haemoglobinometry.

Abstract

An analysis of haemoglobin estimations in a routine laboratory shows that quality control methods based on mean values are unsatisfactory. The use of a cusum method together with control samples is a sensitive and convenient technique for the early discovery of minor deviations in results and it is not dependent on a stable population of patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Cavill. 1971. Quality control in routine haemoglobinometry.. https://doi.org/10.1136/jcp.24.8.701