Data processing in haematology.

Abstract

The output from a Coulter model S is captured by a specially designed silent interface which visualizes the results, automatically prints the data on a continuous paper roll and transmits the information to a card punch located in a data processing room. Further requested test data and patient identification data are subsequently added manually to the punch card. The completed deck of cards is used in an off-line batch mode on a dedicated laboratory computer to format report documents, produce ward listings, and quality control information. A punch card off-line method is also described for blood group and related data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M G Nelson, E Elder. 1972. Data processing in haematology.. https://doi.org/10.1136/jcp.25.7.594

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Collection, storage, and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis.

The benefits of high-throughput bioanalysis within the pharmaceutical industry are well established. One of the most significant bottlenecks in bioanalysis is transferring in vivo-generated study samples from their collection tubes during sample preparation and extraction. In most cases, the plasma samples must be stored frozen prior to analysis, and the freeze/thaw (F/T) process introduces thrombin clots that are capable of plugging pipets and automated liquid-transfer systems. A new approach to dealing with this problem involves the use of Ansys Captiva 96-well 20-microm polypropylene filter plates to collect, store frozen, and filter plasma samples prior to bioanalysis. The samples are collected from the test subjects, and the corresponding plasma samples are placed directly into the wells of the filter plate. Two Duoseal (patent pending) covers are used to seal the top and bottom of the plate, and the plate is stored at down to -70 degrees C. Prior to sample analysis, the seals are removed and the plate is placed in a 96-well SPE manifold. As the plasma thaws, it passes (by gravity or mild vacuum) through the polypropylene filter into a 96-well collection plate. A multichannel pipet or automated liquid-transfer system is used to transfer sample aliquots without fear of plugging. A significant advantage of this approach is that, unlike other methods, issues related to incomplete pipetting are virtually eliminated. The entire process is rapid since thawing and filtering take place simultaneously, and if a second F/T cycle is required for reanalysis, it is not necessary to refilter the samples (additional clotting was not observed after three F/T cycles). This technique was tested using monkey, rat, and dog plasma and sodium heparin and EDTA anticoagulants. To assess the possibility of nonspecific binding to the polypropylene filter, a variety of drug candidates from diverse drug classes were studied. Validation data generated for two Lilly compounds from distinct classes, before and after filtering, are presented in this paper as practical examples of this technique. While LC/MS/MS is the primary method of bioanalysis in our laboratory, the technique presented in this paper is applicable to other forms of detection as well.

Autoanalysis↗

Usefulness of automated chromatography for rapid fetal blood analysis for second trimester prenatal diagnosis of beta-thalassemia.

Prenatal diagnosis of beta-thalassemia is now ideally done in the first trimester of pregnancy by chorionic villus tissue DNA analysis. Nevertheless, fetal blood analysis in the second trimester is required either when the mutation in both parents cannot be characterised or when the couple comes late for investigations. We evaluated the usefulness of analysis of fetal blood on the Biorad Variant Hemoglobin Testing System using the beta-thalassemia short programme in comparison with the conventional globin biosynthesis in 58 pregnancies. The beta/alpha biosynthesis ratios in 13 homozygous fetuses ranged from 0 to 0.03 and the adult hemoglobin (HbA) levels by automated chromatography varied from 0% to 0.4%. The normal or heterozygous fetuses had beta/alpha ratios of >0.04 and HbA levels ranging from 2.1% to 10.6%. In 17 fetuses we also correlated the beta gene mutations with the predicted genotypes using automated high-performance liquid chromatography (HPLC). Follow-up of 18 unaffected fetuses using the Variant System at birth showed a significant increase in HbA levels.

Autoanalysis↗