Search PubMedSearch

PubMed · 5018527

Foood additives.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G O Kermode. 1972. Foood additives.. https://doi.org/10.1038/scientificamerican0372-15

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reducing cellular autofluorescence in flow cytometry: an in situ method.

Cellular autofluorescence affects the sensitivity of flow cytometric assays by interfering with detection of low level specific fluorescence. These detection limits increase with use of protocols, such as thermocycling and fluorescent in-situ hybridization (FISH), that can increase intrinsic cellular fluorescence to 5,000-20,000 fluorescein isothiocyanate (FITC) equivalents. In order to improve signal to noise ratios when using FITC labeled probes in these procedures, we employed a method using the polyanionic azo dye, trypan blue, to reduce intracellular autofluorescence. Dyes such as these are commonly used in immunofluorescent microscopy to reduce background fluorescence. By using this method, we realized an approximately 5-fold increase in signal to noise ratio (S/N) in the direct detection of RNA target probes using flow cytometry. Trypan blue aided in the resolution of dim surface antibodies, internal markers and probes, and functions to reduce background autofluorescence after thermocycling and hybridization. This technique is rapid and easily applicable for reducing intracellular autofluorescence, and can be used in single and dual color applications.

Coloring Agents

Sensitive reverse staining of bacterial lipopolysaccharides on polyacrylamide gels by using zinc and imidazole salts.

We present a new method for visualizing bacterial lipopolysaccharides (LPS)/lipooligosaccharides (LOS) electrophoresed in sodium dodecyl sulfate-polyacrylamide gels. After electrophoresis, gels are washed in boiling water to appreciably remove remaining electrophoresis reagents, then incubated in 10 mM zinc sulfate for 15 min, and subsequently immersed in 0.2 M imidazole for 3 min. As a result, zinc salts precipitate all over the gel surface except in the zones occupied by LPS/LOS, which appear as transparent, colorless bands. Gels can be stored in distilled water for weeks without loss of the negative image. The sensitivity of this stain is similar to that of silver. We believe that zinc-imidazole may be a suitable nontoxic alternative to silver in the rapid analysis of LPS/LOS by polyacrylamide gel electrophoresis.

Coloring Agents

Versatile low-viscosity sieving matrices for nondenaturing DNA separations using capillary array electrophoresis.

The high-resolution separation of double-stranded DNA (dsDNA) has important applications in physical mapping strategies and in the analysis of polymerase chain reaction (PCR) products. Although high-resolution separations of dsDNA by capillary electrophoresis (CE) have been reported, pulsed fields were required to achieve complete resolution of DNA fragments beyond 23 kilobase pairs (kbp). Here, we report a single formulation to separate a broad range (80 bp-40 kbp) of DNA fragments without the use of pulsed fields. We used a low-viscosity sieving medium (ca. 5 cP, at 25 degrees C) based on polyethyleneoxide (PEO) to separate DNA fragments up to 40 kbp. The matrix contained a mixture of 0.5% PEO (Mn 10(6)) to separate fragments up to 1.5 kbp, combined with 0.1% PEO (Mn 8 x 10(6)) to separate fragments between 1-40 kbp, within a single run. All PEO matrix formulations tested were compatible with a variety of intercalating dyes and with two different capillary wall coating methods. We obtained a detection limit of 25 fg of a 200 bp DNA quantitation standard using Vistra Green in the matrix. Resolution was best using short injection times (5 s or less) and low field strengths (approximately 100 V/cm). Sample runs were complete in 70 min, and use of the capillary array electrophoresis (CAE) system permitted high-throughput DNA analysis. The size range separated is approximately 10 times greater than with conventional slab gel separations.

Coloring Agents