Search PubMedSearch

PubMed · 4970764

Human prothrombin activation.

Abstract

Antiserums to human prothrontbin contain antibodies directed against at least two different antigenic sites. During blood coagulation, prothrombin is cleaved into two major antigenically distinct fragments-thrombin and a "pro" fragment. The latter is present in normal seruim, whereas thrombin loses its immunologic reactivity, presumably because of its combination with the natural thrombin inhibitors in blood.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S S Shapiro. 1968-10-04. Human prothrombin activation.. https://doi.org/10.1126/science.162.3849.127

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Kinetic modeling and analysis of a vesicle system for immunosensor development.

A novel mechanism is presented for immunosensor development that uses an immunological competition reaction in a vesicle system. This system consists of a suspension of reconstituted vesicles, channel agonist, protein linker to block the channels, voltage sensitive dye and analyte to be detected. In the proposed mechanism analyte serves a catalytic role as individual analytes competitively displace multiple channel linkers through association with one channel, dissociation and new associations with other channels. When one channel opens on a vesicle a permanent Nernst potential develops for that vesicle leading to fluorescence of voltage sensitive dyes. The time constant of the redistribution from linker-channel form to analyte-channel form is 0.92/k4 (k4 is the off-rate constant for the analyte-channel association) in the region of analyte concentrations less than 10(-9) M. Kinetic analyses show that several factors, including concentration of analyte or linker, number of channels per vesicle, on-rate or off-rate constant of the linker-channel and on-rate constant of analyte-channel complexes have significant effects on the minimum signal response time.

Antigen-Antibody Reactions

Prevalence of hepatitis C virus and genotype distribution in an Australian volunteer blood donor population.

BACKGROUND: This study was undertaken to assess the prevalence of hepatitis C virus (HCV) antibody and RNA in first-time blood donors and to examine the HCV genotype distribution. STUDY DESIGN AND METHODS: A third-generation enzyme-linked immunosorbent assay (ELISA) was used to screen 34,725 donors for HCV antibodies. Donors who were repeatably reactive were tested in two immunoblot assays-a second-generation and a third-generation recombinant immunoblot assay-as well as by a polymerase chain reaction (PCR) assay. PCR-positive donors were genotyped. All samples were screened for alanine aminotransferase levels. RESULTS: The ELISA repeat reactivity rate was 0.55 percent. PCR testing showed that 69 (38%) of the 183 ELISA-reactive samples contained HCV RNA. The third-generation recombinant immunoblot assay identified all 69 viremic samples as antibody positive; however, only 63 tested positive on the second-generation immunoblot. The remaining six PCR-positive donors tested antibody-indeterminate to the core peptide. All six of these donors had HCV subtype 3a infections. Genotype distribution among 58 samples showed that 34 were type 1, of which 22 could be further subtyped as 1a (16) and 1b (6); 2 were 2a; 5 were 2b; and 17 were subtyped as 3a. Donors infected with 2b and 3a had reduced antibody reactivity to the NS4 and NS3 peptides only on the second-generation immunoblot. CONCLUSION: The prevalence of confirmed anti-HCV and viral RNA in new donors is 0.29 and 0.2 percent, respectively. The third-generation recombinant immunoblot assay was more sensitive than the second-generation immunoblot assay in detecting 2b and 3a HCV subtypes. The inclusion of the NS5 peptide in the third-generation recombinant immunoblot did not result in positive tests in any additional donors. Rather, the improvement was due to the increased detection of NS3 and, to a lesser extent, NS4 antibodies. Subtypes 1a and 3a were most prevalent in this population.

Antigen-Antibody Reactions

Simultaneous determination of cross-reactive leukotrienes in biological matrices using on-line liquid chromatography immunochemical detection.

Sulfidopeptide leukotrienes, which are important biomarkers for several diseases, are commonly measured by microtiter plate immunoassays. These immunoassays, however, cannot distinguish between several structurally similar leukotrienes and their cross-reactive metabolites and, therefore, need extensive sample handling and fractionation by means of liquid chromatography (LC). This paper describes the development and automation of a continuous-flow immunochemical detection (ICD) system and its subsequent on-line coupling to LC. The on-line LC-ICD system based on fluorescence-labeled leukotriene E4 (LTE4) was used to determine sulfidopeptide leukotrienes and their cross-reactive metabolites in a single run. Furthermore, biological matrices, e.g., urine and human cell extracts, were analyzed, the only sample pretreatment being on-line solid-phase extraction (SPE) on a novel RP-C4 restricted-access support. The determination limit of LTE4 in urine was 0.2 ng/mL (800 fmol; injection volume, 2000 microL; signal-to-noise ratio, 10). The system was linear from 0.2 to 1.0 ng/mL LTE4. Using nonlinear curve-fitting, the range could be expanded to 2.5 ng/mL. It is shown that, besides quantitation of known analytes, on-line LC-ICD is useful in the discovery of cross-reactive LTE4 metabolites.

Antigen-Antibody Reactions