Search PubMed⌕ Search

PubMed · 4910370

[Electrogalvanic dies].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Macagno. 1970. [Electrogalvanic dies].. https://pubmed.ncbi.nlm.nih.gov/4910370/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper↗

Redox behavior of melanins: direct electrochemistry of dihydroxyindole-melanin and its Cu and Zn adducts.

Synthetic melanin films, formed on electrode surfaces by oxidative polymerization of 5,6-dihydroxyindole solution, were used to directly measure the chromophore's redox reactivity. Films on optically transparent indium-tin oxide (ITO) electrodes allow correlation of spectral changes with electrochemical potential. Spectroelectrochemical titrations show an initial reversible transformation that is ascribed to formation of a unique quinone-imine chromophore. The apparent E(1/2) for maximum quinone-imine formation is approximately 125 mV (vs. Ag/AgCl) but at potentials higher than 100 mV, an irreversible bleaching is evident. Correlation of the current with the monomer concentration implies that only one in six monomers is oxidized to the quinone-imine before the irreversible bleaching occurs. Films pretreated with CuCl(2) and Zn(CH(3)COO)(2) show elevated quinone-imine absorbances, even under reducing conditions, indicating a preferential stabilization of this state by coordination to the metals.

Copper↗

FTIR study of glyphosate-copper complexes.

Complexes of the herbicide glyphosate (GPS) and the heavy metal Cu were studied by infrared spectroscopy under controlled pH, in order to know the mechanisms involved in the formation of these complexes. In CuGPS(-), the IR spectrum shows participation of the carboxylate and phosphonic moieties of the GPS molecule. The formation of the complex produces a lower symmetry in the phosphonate group because of loss of the resonance situation of PO(3)(2)(-) groups, with a subsequent split of their absorption bands. Carboxylate groups are participating by forming unidentate complexes. No conclusion is reached about the involvement of the amino group, but previous EPR findings indicate coordination of GPS to Cu via nitrogen. Consequently, glyphosate in this complex functions with a tridentate character by forming two chelate rings. A study of the CuGPSH species was not possible due to overlapping of its absorption bands with those of free GPS species.

Copper↗