Search PubMed⌕ Search

PubMed · 4773305

Mössbauer spectroscopy.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T H Moss. 1973. Mössbauer spectroscopy.. https://doi.org/10.1016/s0076-6879(73)27038-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design, construction, and performance of an asymmetrical collimator for a cobalt unit.

PURPOSE: Besides four linear accelerators, our institute has a 100-cm SAD cobalt unit which has some specific and useful features for radiotherapy. The unit is equipped with a electronic portal imaging device (EPID) and an asymmetrical collimator to perform similar treatment techniques as on the linear accelerators, using the same shielding and half-beam techniques. The design, construction, and performance of the asymmetrical collimator are described. METHODS AND MATERIALS: The new design includes the doubling of the drive and read-outs for both X and Y jaws. Spare parts of the standard collimator provided by the manufacturer were used as much as possible. Special trimmers were designed to allow asymmetry to the center of the field. The trimmers are removable, but the design allows the use of trimmers, wedges, and shadow tray simultaneously. RESULTS: Transmission through the trimmers is less than 5% of the dose at d(max). The use of the trimmers extends the source to diaphragm distance to 53 cm, resulting in a smaller penumbra as compared to the standard collimator. Without the trimmers, the maximum field size remains unchanged, i.e., 40 x 40 cm(2); with the trimmers, it is 38 x 36 cm(2). Percentage depth doses and output factors were similar to the standard collimator. CONCLUSION: The modified collimator is compact and allows use of the same shielding blocks as the linear accelerators, providing the same treatment techniques and capabilities. This simplifies an exchange of patients between our treatment machines.

Cobalt Radioisotopes↗

The ESTRO-EQUAL Quality Assurance Network for photon and electron radiotherapy beams in Germany.

BACKGROUND: In 1998 an ESTRO Quality Assurance Network for radiotherapy (EQUAL) has been set up for 25 European countries for photon and electron beams in reference and non-reference conditions. MATERIAL AND METHODS: Measurements are done using LiF powder (DTL937-Philitech, France) that is processed with the PCL3 automatic reader (Fimel-PTW). The participating centers irradiate the TLDs with an absorbed dose of 2 Gy according to the clinical routine. RESULTS: Until September 2000 EQUAL has checked 135 photon beams (including the beams rechecked) from 51 radiotherapy centers in Germany out of 86 accepted centers. The results show that 2% of the beam outputs in reference conditions and 3% of the percentage depth doses are outside the tolerance level (deviation > +/- 5%). 6% of the beam output variations and of the wedge transmission factors show deviations > +/- 5%. The global analysis of results shows deviations > +/- 5% in at least one parameter for 18 beams out of the 135 beams checked. Five rechecked beams present one "real dosimetric" problem in one or more parameters, corresponding to 4% of the 114 beams for which the deviations cannot be attributed to set-up errors.--The EQUAL network has checked 89 electron beams in Germany. The results show that all beam outputs checked are within the tolerance level. The standard deviation for the beam output in reference conditions is 2.0% and 2.2% for the beam output for the others field sizes. The percentage of deviations > 3% and < or = 5% for the reference beam output is higher for electron beams than for photon beam checks. Therefore the electron beam calibration and the TPS algorithms should be improved to increase the accuracy of the patient dosimetry for radiotherapy. CONCLUSION: EQUAL program demonstrates a consistency in radiotherapy dosimetry for photon and electron beams resulting in a satisfying accuracy of the dosimetry in Germany.

Cobalt Radioisotopes↗

External audits of electron beams using mailed TLD dosimetry: preliminary results.

AIM: A feasibility study has been performed to investigate the possibility of using mailed thermoluminescence dosimetry (TLD) for external audits of clinical electron beams in Europe. METHODS: In the frame of the EC Network Project for Quality Assurance in Radiotherapy, instruction sheets and mailing procedures have been defined for mailed TLD dosimetry using the dedicated holder developed by a panel of experts of the International Atomic Energy Agency (IAEA). Three hundred and thirty electron beam set-ups have been checked in the reference centres and some local centres of the EC Network Project and in addition through the centres participating to the EORTC Radiotherapy Group trial 22922. RESULTS: The mean ratio of measured dose to stated dose is 0.2% and the standard deviation of measured dose to stated dose is 3.2%. In seven beam set-ups, deviations greater than 10% were observed (max. 66%), showing the usefulness of these checks. CONCLUSION: The results of this feasibility study (instruction sheets, mailing procedures, holder) are presently endorsed by the EQUAL-ESTRO structure in order to offer in the future to all ESTRO members the possibility to request external audits of clinical electron beams.

Cobalt Radioisotopes↗