Search PubMed⌕ Search

PubMed · 4592740

A technique for precision removable partial denture construction.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C B Rushford. 1974. A technique for precision removable partial denture construction.. https://doi.org/10.1016/0022-3913(74)90145-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimization of operator and physical parameters for laser welding of dental materials.

OBJECTIVE: Interactions between lasers and materials are very complex phenomena. The success of laser welding procedures in dental metals depends on the operator's control of many parameters. The aims of this study were to evaluate factors relating to the operator's dexterity and the choice of the welding parameters (power, pulse duration and therefore energy), which are recognized determinants of weld quality. DESIGN: In vitro laboratory study. MATERIALS AND METHODS: FeNiCr dental drawn wires were chosen for these experiments because their properties are well known. Different diameters of wires were laser welded, then tested in tension and compared to the control material as extruded, in order to evaluate the quality of the welding. Scanning electron microscopy of the fractured zone and micrograph observations perpendicular and parallel to the wire axis were also conducted in order to analyse the depth penetration and the quality of the microstructure. Additionally, the micro-hardness (Vickers type) was measured both in the welded and the heat-affected zones and then compared to the non-welded alloy. RESULTS: Adequate combination of energy and pulse duration with the power set in the range between 0.8 to 1 kW appears to improve penetration depth of the laser beam and success of the welding procedure. Operator skill is also an important variable. CONCLUSION: The variation in laser weld quality in dental FeNiCr wires attributable to operator skill can be minimized by optimization of the physical welding parameters.

Chromium Alloys↗

Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys.

Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supported prostheses obtained in Ni-Cr-Ti alloy, compared to a semi-noble alloy Pd-Ag. Eight superstructures for each alloy were produced over 4 implants in the anterior region of the mandible. The superstructures were placed in a torquemeter and the fixation screw of implant #1 was tightened with a 20 Ncm load with the others loosened (Sheffield test). The unfitness (in mm) was measured using a three-dimensional optical measurer in each implant, in the buccal and lingual aspects. The obtained data were submitted to statistical analysis by the analysis of variance and Tukey's test at 5% level. Significant differences were found for the factors material (p< or =0.05), with Ni-Cr-Ti pieces better than Pd-Ag ones, and implants (p< or =0.01). There were no significant differences for the factor position and interactions among factors (p>0.05). Based on the analysis of the data, it is possible to conclude that the Ni-Cr-Ti alloy makes possible the obtainment of one-piece implant-supported superstructures with a smaller misfit compared to the one obtained in Pd-Ag alloy, traditionally indicated for this situation. Additional tests may verify the superiority of the Ni-Cr-Ti alloy.

Chromium Alloys↗

Wear evaluation of cobalt-chromium alloy for use in a metal-on-metal hip prosthesis.

Wear of the polyethylene in total joint prostheses has been a source of morbidity and early device failure, which has been extensively reported in the last 20 years. Although research continues to attempt to reduce the wear of polyethylene joint-bearing surfaces by modifications in polymer processing, there is a renewed interest in the use of metal-on-metal bearing couples for hip prostheses. Wear testing of total hip replacement systems involving the couple of metal or ceramic heads on polymeric acetabular components has been performed and reported, but, until recently, there has been little data published for pin-on-disk or hip-simulator wear studies involving the combination of a metallic femoral head component with an acetabular cup composed of the same or a dissimilar metal. This study investigated the in vitro wear resistance of two cobalt/chromium/molybdenum alloys, which differed primarily in the carbon content, as potential alloys for use in a metal-on-metal hip-bearing couple. The results of pin-on-disk testing showed that the alloy with the higher (0.25%) carbon content was more wear resistant, and this alloy was therefore chosen for testing in a hip-simulator system, which modeled the loads and motions that might be exerted clinically. Comparison of the results of metal-on-polyethylene samples to metal-on-metal samples showed that the volumetric wear of the metal-on-polyethylene bearing couple after 5,000,000 cycles was 110-180 times that for the metal-bearing couple. Polyethylene and metal particles retrieved from either the lubricant for pin-on-disk testing or hip simulator testing were characterized and compared with particles retrieved from periprosthetic tissues by other researchers, and found to be similar. Based upon the results of this study, metal-on-metal hip prostheses manufactured from the high carbon cobalt/chromium alloy that was investigated hold sufficient promise to justify human clinical trials.

Chromium Alloys↗