Quantitation of hemoglobin A2. An interlaboratory study.

Abstract

In the 1976 hemoglobinopathy proficiency testing survey of the Center for Disease Control (CDC), whole-blood samples from hematologically normal adults and from individuals heterozygous for beta-thalassemia were shipped to survey participants. The object of this survey was to determine the state of the art for technics used to quantitate hemoglobin A2 (Hb A2) and to test the ability of laboratories to differentiate between blood samples having normal Hb A2 levels and those having elevated levels (i.e., those from individuals with beta-thalassemia trait). The results of Hb A2 quantitation obtained from 183 volunteer participant laboratories were compared with those obtained from 24 reference laboratories. Individual values varied greatly among laboratories and among methods for both normal and elevated Hb A2 samples. The results returned by many laboratories were not within 2 SD of the reference laboratory mean and also were not sufficiently accurate to differentiate between the normal blood samples and those with beta-thalassemia trait. The results suggest that methods for quantitating Hb A2 need to be standardized and a suitable method for determining laboratory performance found.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R M Schmidt, E M Brosious. 1979. Quantitation of hemoglobin A2. An interlaboratory study.. https://doi.org/10.1093/ajcp%2F71.5.534

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An evaluation of the Ramco kit for serum ferritin assay.

The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6 micrograms/l to greater than 2 000 micrograms/l there was a correlation coefficient between the two methods of 0,8284 (P less than 0.001). It is concluded that the Ramco kit is suitable for use in clinical practice.

Blood Chemical Analysis

Use of microbore columns for the separation of substances of biological origin.

A gradient system for use with microbore columns is described and the repeatability of the system determined. A simple sampling device for use with aqueous biological samples is described, and the advantages of the high mass sensitivity of microbore columns for the analysis of such samples are discussed. The sensitivity of the system is demonstrated by the determination of acetophenone in water at a level of one part per billion. The use of the apparatus for the separation of low-molecular-weight, non-ionic compounds contained in blood is also demonstrated. It is shown that excellent separations of such components can be obtained from as little as 400 microliter of serum.

Blood Chemical Analysis