Search PubMedSearch

PubMed · 4510753

[The jacket crown].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H A Kreutzmann. 1972. [The jacket crown].. https://pubmed.ncbi.nlm.nih.gov/4510753/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiographic inspection of dental castings.

Underdimensioning may adversely affect the clinical use of a crown or bridge. Insufficient dimensions may be due to inadequate modelling or deficiencies caused by the casting process. The dimensions of cast objects are measured mechanically using a calliper. This method has often proved to be insufficient in detecting areas of too small dimensions. This paper presents a non-destructive method of inspecting dental castings using radiography. The occlusal thickness of a random sample of 150 crowns made during regular clinical treatment in our department was inspected mechanically and radiographically. We found that 19% of the crowns were only 0.1 mm thick or less at the thinnest spot, 18% were between 0.1 and 0.2 mm and 9% were between 0.2 and 0.3 mm. In comparison to mechanical examination, radiographic inspection usually showed smaller values.

Crowns

Macromolecular leakage beneath full cast crowns. Part III: The diffusion of lipopolysaccharide and dextran.

STATEMENT OF PROBLEM: Most microleakage studies have used low molecular weight dyes or isotopes rather than clinically relevant materials, such as lipopolysaccharides or cell wall materials, that have been shown to provoke inflammatory reactions in the dental pulp. PURPOSE: This study evaluated the leakage (diffusion) of lipopolysaccharide and dextran beneath cast gold crowns luted with 3 cements. MATERIALS AND METHODS: Thirty extracted molars were prepared for crowns. Ten crowns with access ports (facial or lingual) were cast in gold and luted with zinc phosphate, glass ionomer, and an adhesive resin cement onto their preparations. Teeth and crowns with filters inserted into the ports were immersed in a solution of labeled macromolecules (TRITC-LPS, FITC-dextran) and evaluated for leakage at 2 weeks, and 1, 2, 3, 4, 5, and 6 months. Filters were retrieved and analyzed with fluorescent microscopy. RESULTS: All filters retrieved from crowns luted with zinc phosphate, glass ionomer, and adhesive resin cements demonstrated no detectable leakage and were negative for both FITC-dextran and TRITC-lipopolysaccharide at all evaluation periods. CONCLUSION: Leakage of lipopolysaccharides and dextran did not occur during the period of this study. For the length of this investigation, zinc phosphate, Ketac-Cem, and C&B-Metabond were equally effective at preventing leakage of detectable molecular concentrations of lipopolysaccharide and dextran to the level of the access ports.

Crowns

Marginal fit and surface roughness of crowns made with an accelerated casting technique.

STATEMENT OF PROBLEM: Conventional investing and casting techniques following the manufactures' recommendations are time-consuming. Accelerated casting techniques have been reported, but their accuracy has not been adequately studied for complete crown castings. PURPOSE: This study evaluated the marginal fit and surface roughness of complete crowns made with a conventional and an accelerated casting technique. MATERIALS AND METHODS: Part I of the study determined the mean time interval required for each investment to reach its maximum exothermic setting reaction temperature. Part II determined the marginal discrepancy of standardized complete crowns cast in a high noble metal ceramic alloy, with the use of four phosphate-bonded investments. A conventional technique (as recommended by the manufacturer) was compared with an accelerated technique that used 13- to 17-minute bench set time (as determined in part 1 for each investment)_ and 15-minute wax elimination cycle in a 815 degrees C (1500 degrees F) preheated furnace. Part III evaluated the surface roughness of castings made with the same techniques as in part II. RESULTS: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated casting technique were not significantly (P > 0.05) different from those fabricated with the conventional technique. CONCLUSION: The accelerated casting technique described in this study could be a vital alternative to the time-consuming conventional techniques.

Crowns